説明
Thermoelectric Solar Total Radiation Transmitter Solar Radiation Photometer Sensor 10V30V for Outdoor NO.8944
Feature 1Using standard RTU 485 communication protocol, it can directly read the current total solar radiation value, and the wiring method is simple. 2High measurement accuracy, using pyroelectric sensor elements, short response time, small error, small temperature compensation, and more accurate measurement within the range. 3The pyroelectric total solar radiation transmitter has beautiful appearance, small installation space, and the spectral range reaches 0.3~3m. 4The light transmittance is as high as 95%, and the transparent doublelayer glass cover has good sensitivity and special surface treatment to prevent dust adsorption. 5Products are widely used in solar energy utilization, meteorology, agriculture, building materials aging and air pollution departments to measure solar radiant energy.Item Type: Sun Radiation SensorMaterial: AluminumWeight: Approx. 1074g / 37.9ozWidth: Approx. 15.5cm / 6.1inHeight: Approx. 8.5cm / 3.3inModel: RS-TBQ-N01-AL1. Parameter information:
RS-
Company code
TRA-
Total Solar Radiation Transmitter
N01-
485 output (standard RTU)
AL
Aluminum housing
Power supply range
10V-30V DC
Output method
485 (standard RTU protocol)
Power consumption
0.8W
Working temperature
-40~60
Working humidity
0%~100%RH
Sensitive
7-14VW-1
Internal resistance
About 250-400
Response time (99%)
30s
Non-linear error
3%
Corresponding error of direction
30W/m
Temperature response error
8% (-40-+40)
Spectral range
0.3~3m
Measuring range
0-2000W/m
Resolution
1W/m
Accuracy
3%
Annual stability
3%
Spectral selectivity
10%
Cosine response error
5%
Tilt response error
2%
2. Wire installation method:
Line color
Description
Power
Brown
Power (10~30V DC)
Black
Power supply negative
Output
Yellow
485-A
Blue
485-B
3. Basic communication parameters:
Code
8-bit binary
Data bits
8 bits
Parity bit
No
Stop bit
one bit
Error checking
CRC (Redundant Cyclic Code)
Baud rate
Can be set to 2400bit/s, 4800bit/s, 9600bit/s, the factory default is 4800bit/s
4. Data frame format definition:UsingRTU communication protocol, the format is as follows:Time for initial structure 4 bytesAddress code = 1 byteFunction code = 1 byteData area = N bytesError check = 16-bit CRC codeEnd time structure 4 bytesAddress code: The address of the transmitter, which is unique in the communication internet(factory default 0x01).Function code: Command function instruction issued by the host, the transmitter can use function code 0x03 (read register data) and 0x06 (write register).Data area: The data area is the specific communication data. First, pay attention to the high byte of the 16-bit data!CRC code: double-byte check code.5. Troubleshooting1. If the reading is 0, check whether the protective cover of the product has been removed and whether there is sunlight2. Please check if the 485 wiring is correct3. Check whether the power supply meets the sign4. Equipment damage6. Product Maintenance1. The glass cover should be kept smooth and clean, often wiped with a soft cloth or fur2. There should be no water in the glass cover. If you encounter long-term weather such as heavy rain, snow, ice, etc., it is recommended to cover3. It is recommended to check whether the desiccant in the dryer is damp regularly. The specific manifestation is that orange has turned into a dark color. If this happens, the desiccant should be replaced in time, or the desiccant should be taken out and dried and reused4. After the equipment has been used for more than two years, the sensitivity must be recalibrated by the manufacturer or measurement department
.wang-edit-text{
font-family:'Arial' !important;
}
.wang-edit-text table {
border-t
-
Fruugo ID:
296155091-662361728
-
EAN:
7987249298944
製品安全情報
以下に概説するこの製品に固有の製品安全性情報を参照してください。
以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。
製品安全ラベル
安全上の警告:
Not suitable for children under 36 months. Choking Hazard. Adult supervision recommended