Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

¥2,049
配送料無料

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

  • ブランド: Unbranded

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

  • ブランド: Unbranded
価格: ¥2,049
販売元:
¥2,049
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

Item Type:Relay Module Product Model: YF-11 Input Voltage:DC7-24V Output Power: Can Control DC Power Load within 10A Time Range: 0.01 Second to 999 Minutes, Any Time Adjustable Function: Pulse Trigger Cycle, Timing, Delay, Power Tube, mos Tube, Field Effect Tube, Switch, Relay Switch Application: It is Often Used to Control Motors, LED Light Strips, DC Motors, Micro Water Pumps, Solenoid Valves, Etc. P-21: Give the signal, after a delay of A second, the output starts P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops P-24: There is a signal. After A second, the output starts, and after the signal disappears for more than A second, the output stops. P-25: When there is a signal, the output will start after A second, and the output will stop when there is another signal for more than A second P-26: There is a signal, the output stops after A second, and the signal disappears and the output stops after A second. P-27: Detection of a pulse signal, the output stops no pulse signal, more than A second output start (the signal continues or the signal disappears are regarded as no pulse signal) P-28: After power on, after a delay of A second, the output starts until the power is off P-31: After power on, the output starts for A second, stops for B second, infinite loop power off stops P-32: When there is a signal, start P-31 infinite loop when the signal disappears, terminate the loop P-33: Give a signal to start P-31 infinite loop give another signal to terminate the loop P-34: After power-on, after a delay of A second, the output will start, and it will stop after closing B seconds P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull-in for B seconds P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped. P-37: When there is a signal, the output starts and stops automatically for A second, and then counts for B seconds after it stops. The signal trigger is invalid within AandB time P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops P-41: No action with signal trigger when signal disappears disconnect after output start delay A time P-42: The signal disappears, after a delay of time A, the output starts working time B ends P-43: The signal disappears. After the time A exceeds, the output starts the working time B ends P-44: After power on, the output will start A time, stop B time cycle C times and automatically stop. P-45: No action when energized, after signal is given output starts A time, stops B time cycle C times and automatically stops Give signal again, execute again P-46: After giving the signal more than A times, the output will start keep the output stop when the power is off P-47: After giving the signal more than A times, the output starts and stops for B seconds P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B seconds 3. Description of button setting: Power on display "" means entering standby state Press K1 for the first time, (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjustment main mode, K3K4 adjustment function Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit) Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit) Press K1 for the fourth time, the display "" means entering the standby state Press K4 in standby mode to permanently turn off or on the display and switch to low power consumption mode 4. The decimal point time unit description: X.XX The decimal point is in hundreds, and the timing range: 0.01 seconds to 9.99 seconds XX.X The decimal point is in the tenth place, timing range: 0.1 second to 99.9 seconds XXX has no decimal point, timing range: 1 second to 999 seconds XXX. The decimal point is in the ones place, and the timing range: 1 minute to 999 minutes Note: Due to the light and screen setting difference, the item's color may be slightly different from the pictures. Please allow slight dimension difference due to different manual measurement.
  • Fruugo ID: 434569827-911853955
  • EAN: 9316197747620

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 月 15 12月 2025–月 22 12月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Foshan Panweibai Trading Co., Ltd.
  • Foshan Panweibai Trading Co., Ltd.
  • Room 103, No. 57, Shalong Road, Jiujiang Town, Nanhai District, Foshan City
  • Foshan
  • CN
  • 528203
  • razer0815@outlook.com
  • 13790744267

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • Jean Luc
  • In Memoria Futuri SAS
  • 3 RUE DU PAS DE LA MULE 75004 PARIS
  • Paris
  • France
  • 75004
  • infoapexchen@gmail.com
  • 33745713901