Digital Manifold Meter For Air Conditioner Refrigerant Leak, Fault Check, Vacuum, And Temperature Testing

¥82,690
配送料無料

Digital Manifold Meter For Air Conditioner Refrigerant Leak, Fault Check, Vacuum, And Temperature Testing

  • ブランド: Ebox

Digital Manifold Meter For Air Conditioner Refrigerant Leak, Fault Check, Vacuum, And Temperature Testing

  • ブランド: Ebox
希望小売価格: ¥165,390
価格: ¥82,690
得する金額: ¥82,700 (50%)
販売元:
¥82,690
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

AC3000 digital manifold is a professional  instrument for installation, testing and maintenance of refrigeration equipment such as air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements ( with optional dual temperature probes ), a 32-bit digital processor and a large LCD in one easy-to-use instrument with the following main functions. 1.Pressure and Saturation Temperature. 2.Vacuum Operation. 3.Pressure Leak Test with recording. 4.Direct T1 T2 Temperature, Real-time Super heat and Sub cooling Simultaneously Display with Optional Two Clamp-on Temperature Probes. 5.89 Refrigerant Profiles Stored in The Instrument. 6.Automatic Multi-unit Pressure Conversion. 7.Automatic Temperature ℃/℉ Conversion. It is the right one you have to do the job right. Pressure Measuring: 1. Turn off the blue valve and red valve. 2. Turn on the instrument. Then verify that LCD displays the status of the pressure test.If not,press the function button to switch it. 3. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero. 4. Press R+/ R- buttons , Unit button and ℃/℉ button to select tested refrigerant and reading display respectively. 5. If the clamp-on temperature probes have been connected to the instrument, the real-time temperature will be displayed.If not, no display of it. 6. Connect the instrument to the refrigeration system according to the chart below. 7. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose. 8. When the refrigeration system stops, turn on the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly. 9. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system. 10. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running. 11. Shut down the refrigeration system,make sure all valves are turned off , then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument. Vacuum Operation: 1. Turn off the blue valve and red valve. 2. Power on the instrument. Then make sure the LCD displays vacuum test status.If not, press the Function button to switch it. 3. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero 4. Press the unit button to adjust the reading unit. 5. Connect the instrument to the refrigeration system.(Connected clamp-on temperature probes will not affect the operation.) 6. Turn on the blue valve and red valve, and start the vacuum pump. 7. After the vacuum operation is completed,turn off the blue valve and red valve, then shut the vacuum pump. At this time,pressure leak test mode can be used to check leakage in the system ( Please refer to Pressure Leak Test). Pressure Leak Test: 1. The instrument is powered on with the blue and red valves turned off. 2. Press the Function button to pressure leak test mode.
  • Fruugo ID: 184331743-393621310
  • EAN: 6264607529348

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

安全上の警告: Keep out of reach of children under 36 months. Contains small parts that may present a choking hazard. Adult supervision required Please read and retain these instructions for future reference Remove all packaging before giving to children Keep away from fire and direct heat sources

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 月 27 10月 2025–月 17 11月 2025 - 無料

アメリカ合衆国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Ebox
  • Ebox Inc
  • Central Ave, Chino,CA,USA
  • Chino
  • US
  • 91710
  • f.help@ebox-inc.com
  • 805 539 4494
  • https://www.ebox-inc.com

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • Axitera GmbH
  • Axitera GmbH
  • Kreuznacher Str. 30, D-60486 Frankfurt a. Main,
  • Hessen, Germany
  • Frankfurt am Main
  • DE
  • 60486
  • successservice3@gmail.com
  • (+49) 6934873848