Universal Circuit Control Board for Sliding Gate Opener Main Electronic Control Board for Sliding Gate Motor 110V

¥5,690
+ 配送料¥449

Universal Circuit Control Board for Sliding Gate Opener Main Electronic Control Board for Sliding Gate Motor 110V

  • ブランド: Unbranded

Universal Circuit Control Board for Sliding Gate Opener Main Electronic Control Board for Sliding Gate Motor 110V

  • ブランド: Unbranded
希望小売価格: ¥7,490
価格: ¥5,690
得する金額: ¥1,800 (24%)
販売元:
¥5,690
+ 配送料¥449

在庫あり

以下の支払い方法を利用することができます

説明

Universal Circuit Control Board for Sliding Gate Opener Main Electronic Control Board for Sliding Gate Motor 110V Item Type: Sliding Gate Opener Control Board Material: Electron Component Weight: Approx. 316g / 11.1oz Applicable Scope: Motor Controller Type: Automatic Door Opener Applicable Product: Sliding Door Product Size: Approx. 130x108mm / 5.1x4.3in Remote Control Learning Method: Press the remote control learning key on the controller for 1 second, release it when the LED6 indicator is off, then press and hold any key on the remote control without moving, the indicator will flash three times to indicate completion. The remote control can be used normally. The same method can be used to learn the second, third, etc. remote controls. Remote Control Password Deletion: Hold down the learning key on the controller for about 8 seconds, release it after hearing a prompt tone, and clear all previously learned remote controls. You can relearn and use them according to the remote control learning method. Remote Control Usage: The controller can learn up to 300 learning codes. If the number exceeds this limit, no more controllers can be added. You can only delete some before adding more remote controls. Remote Control Keyboard Operation: Pressing the direction (open, close) key on the remote control can make the motor move. Pressing the stop key on the remote control can stop the motor or unlock the remote control keys. Lock Manual Keyboard: When B2 is switched to ON, pressing the lock button on the remote control will lock the controller (the stop indicator on the panel will flash), only locking the manual buttons and remote control direction keys. Press the stop key on the remote control to unlock (the stop indicator on the panel stops flashing). In the locked state of the controller, you must unlock it by pressing the stop key on the remote control before using the direction keys on the remote control and the manual buttons on the controller. Manual Door Closing Function Setting: Users can set the automatic door closing function according to their needs. When B3 is set to ON, it indicates that the automatic door closing function is enabled. When set to OFF, it indicates that the automatic door closing function is disabled. Automatic Door Closing Setting Method: Pull up the red jumper B3 and B6 to ON. Set the delayed door closing time by pressing the function key F(SN1) once for each additional second. After setting the desired time, B6 must be pulled down to the OFF position, and there will be an audible prompt, indicating that the automatic door closing time is set. External Manual Switch Wiring: External single button manual: An optional doorbell switch can be connected to the COM and ONE terminals. Single button manual operates in a cycle mode: Open-Stop-Close-Stop. Card Swipe Door Opening: Specifically used for door opening function, the common line is connected to GND, and the open line is connected to OP. Note: When using the card swipe function, the controller can set the automatic door closing function to ensure that the door closes after a delayed time (refer to automatic door closing setting). However, for safety purposes, it is necessary to install infrared detection devices to prevent any objects from being trapped during automatic door closing. Travel Wiring: Travel can be selected using either mechanical or reed tube methods. The common line of travel is connected to COM, and the direction is connected to O.P and C.L. Motor Wiring: The motor wiring must be done according to the main diagram. The common line of the motor must be connected to the COM of the circuit board, and the direction is connected to L1 and L2. Otherwise, there may be a malfunction of the motor rotating in one direction only. Motor Protection Time Setting: (This function must be used with B3 in a certain position. If the indicator does not turn off, you must power off and re enter this function). After the door is installed (when the travel corresponds to the stop position), power off for 5 seconds and then power on. Immediately hold down the function key F for more than 5 seconds. After the door moves, release the button. The door will first open to the travel position and then automatically execute the closing action. After closing to the travel position, it will stop, completing the motor protection time setting. Finally, B6 must be pulled down to the OFF position.
  • Fruugo ID: 375056842-812051085
  • EAN: 5081306240067

配送と返品

24時間以内に発送

  • STANDARD: ¥449 - 間の配達 金 03 10月 2025–月 13 10月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • shenzhenshijiangjunfudianzishangwuyouxiangongsi
  • shenzhenshijiangjunfudianzishangwuyouxiangongsi
  • BantianjiedaoxiangjiaotangshequzhonghaogongyechengC2dongwuceng505
  • Longgangqu
  • Shenzhenshi
  • Guangdongsheng
  • China
  • 518000
  • Wallace22578@outlook.com
  • +8613084447403

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659