Battery Charge Discharge Module Integrated Timing Undervoltage Overvoltage Protection Board

¥1,899
配送料無料

Battery Charge Discharge Module Integrated Timing Undervoltage Overvoltage Protection Board

  • ブランド: Unbranded

Battery Charge Discharge Module Integrated Timing Undervoltage Overvoltage Protection Board

  • ブランド: Unbranded
希望小売価格: ¥2,449
価格: ¥1,899
得する金額: ¥550 (22%)
販売元:
¥1,899
配送料無料

在庫あり

14日間返品ポリシー

支払い方法:

説明

Battery Charge Discharge Module Integrated Timing Undervoltage Overvoltage Protection Board

Feature:1. AUTOMATICALLY POWER OFF AFTER SETTING: This module can realize battery charge and discharge control, automatically power off after setting2. SET CHARGING AND DISCHARGING TIME: The charging and discharging time can be set, power supply voltage is DC6-40V, voltage detection range is DC0-60V, suitable for various batteries below 60V, and the voltage test error is 0.1V3. SERIAL PORT COMMUNICATION FUNCTION: With serial port communication function, the working status of the relay can be monitored in real time through the serial port4. ADDITIONAL SIGNAL OUTPUT: There is an additional signal output, when the relay conduction condition is met, the output is high, and other devices can be controlled5. ONE KEY EMERGENCY STOP FUNCTION: There is one key emergency stop function (STOP key), with reverse connection protection, reverse connection does not burnSpecification:Item Type: Battery Charge Discharge ModulePower Supply Voltage: DC6-40V, voltage detection range DC 0-60V, suitable for various batteries below 60V, voltage test error 0.1V.Charge And Discharge Time (OP) Range: 0-999 minutes.Operating Mode: Voltage Upper Limit: UL1, voltage lower limit nL1, voltage upper limit must be greater than voltage lower limit (UL1>nL1)U-1: Charging Measurement: When the measured voltage is lower than the lower limit voltage, the relay is closed, and higher than the upper limit voltage, the relay is disconnected;U-2: Charging Measurement Time Control: Set the charging time (OP); when the measured voltage is lower than the lower limit voltage, the relay is closed, and the OP time starts to count down after the pull in. When the time is up, the relay is disconnected; when the voltage is higher than the upper limit voltage, the relay disconnect.U-3: Discharge Detection: When the measured voltage is lower than the lower limit voltage, the relay is disconnected, and when the measured voltage is higher than the upper limit voltage, the relay is closed;U-4: Discharge Detection Time Control: Set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay is closed, and the OP time starts to count down after the pull in. When the time is up, the relay is disconnected; when the measured voltage is lower than the lower limit Voltage, the relay is off;U-5: Closed In The Interval: When the measured voltage is between the upper limit and the lower limit, the relay is closed, otherwise disconnected;U-6: Pull In Outside The Interval: When the measured voltage is lower than the lower limit voltage or higher than the upper limit voltage, the relay is pulled in, and the relay is disconnected in other cases..Package List:1 x Battery Charge Discharge Module
  • Fruugo ID: 426902843-896107192
  • EAN: 7409249065758

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 火 06 1月 2026–火 13 1月 2026 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る