Battery Charge Discharge Module Integrated Board Voltmeter Undervoltage Overvoltage Protection

¥2,449
配送料無料

Battery Charge Discharge Module Integrated Board Voltmeter Undervoltage Overvoltage Protection

  • ブランド: Unbranded

Battery Charge Discharge Module Integrated Board Voltmeter Undervoltage Overvoltage Protection

  • ブランド: Unbranded
希望小売価格: ¥4,349
価格: ¥2,449
得する金額: ¥1,900 (43%)
販売元:
¥2,449
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

Features 1、An additional signal output. When the relay conduction condition is met, the module will output high level to control other devices. 2、With serial port communication function, the working status of the relay can be monitored in real time through the serial port. 3、Charge and discharge time can be set, and the battery charging board will automatically power off after setting. 4、There is a key emergency stop function (STOP key). With reverse connection protection, the reverse connection will not burn. 5、This battery charging module is designed for the batteries below 60V, and the error in voltage measuring is less than 0.1V. Specification Item Type: Battery Charge and Discharge Module Product Material: Printed Circuit Board Product Parameters: 1: Power supply voltage: DC6--40V; Voltage Detection Range: DC 0--60V; Suitable for various batteries below 60V; Voltage Test Error: ±0.1V; 2: Charge and discharge time (OP) range: 0-999 Minutes. How to Use: 1. First determine the working mode of the relay; 2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default U-1 mode), and then enter the main interface,) "Long press the SET button for 2 seconds and then release” to enter the mode selection interface, and select the mode (U-1~U-6) by short pressing the UP and DOWN buttons; 3. After selecting the mode (such as U-1), short press the SET button to set the corresponding parameters. At this time, the parameters to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP conduction time), and press UP, DOWN to adjust the parameter value, supports long press (rapid increase or decrease) and short press (increase or decrease by 1 unit); short press the SET key to set the next parameter of the current mode, the process is the same as above; 4. After setting the parameters of the selected mode, press and hold the SET button for 2 seconds and then release it. The currently set mode will flash, and then return to the main interface. The parameter setting is successful, very simple! 5. On the main interface, short press the DOWN button to switch between voltage and time, which is very simple. Mode Selection Interface: Long press the SET button to enter, after the setting is completed, long press the SET button to exit and return to the main interface, very simple! Operating Mode: Voltage Upper Limit: UL1, Voltage Lower Limit: nL1, voltage upper limit must be greater than voltage lower limit (UL1>nL1) U-1: Charging Measurement: When the measured voltage is lower than the lower limit voltage, the relay is closed, and higher than the upper limit voltage, the relay is disconnected; U-2: Charging Measurement Time Control: Set the charging time (OP); when the measured voltage is lower than the lower limit voltage, the relay is closed, and the OP time starts to count down after the pull-in. When the time is up, the relay is disconnected; when the voltage is higher than the upper limit voltage, the relay disconnect. U-3: Discharge Detection: When the measured voltage is lower than the lower limit voltage, the relay is disconnected, and when the measured voltage is higher than the upper limit voltage, the relay is closed; U-4: Discharge Detection Time Control: Set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay is closed, and the OP time starts to count down after the pull-in. When the time is up, the relay is disconnected; when the measured voltage is lower than the lower limit Voltage, the relay is off; U-5: Closed in the Interval: When the measured voltage is between the upper limit and the lower limit, the relay is closed, otherwise it is disconnected; U-6: Pull-in Outside the Interval: When the measured voltage is lower than the lower limit voltage or higher than the upper limit voltage, the relay is pulled in, and the relay is disconnected in other cases; Package List 1 x Battery Charge Discharge Module
  • Fruugo ID: 271670617-602232403
  • EAN: 9308869135996

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 金 17 10月 2025–木 23 10月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る