Pocket Portable Digital pH Meter Tester Water Quality Testing compatible with Swimming Pool Aquarium

¥2,299
+ 配送料¥1,049

Pocket Portable Digital pH Meter Tester Water Quality Testing compatible with Swimming Pool Aquarium

  • ブランド: Unbranded

Pocket Portable Digital pH Meter Tester Water Quality Testing compatible with Swimming Pool Aquarium

  • ブランド: Unbranded
希望小売価格: ¥3,049
価格: ¥2,299
得する金額: ¥750 (24%)
販売元:
¥2,299
+ 配送料¥1,049

在庫あり

以下の支払い方法を利用することができます

説明

1Waterproof metal electrode and high quality material, not easy to break and durable in use. 2Easy to use and operate, just insert the probe into the liquid and press the button for pH testing. 3Compact structure, lightweight and portable, easy to carry and convenient for indoor and outdoor use. 4Suitable for measuring the pH value of aquarium, fishing, swimming pool, school laboratory, food and beverage. 5This digital pH meter features high accuracy, stable measurement, high reliable and excellent performance. Condition: 100% Brand New Item Type: pH Meter Material: Plastic Working Temperature: 0-50 RH95% (32-122) Measuring pH Range: 0.0-14.0pH Resolution: 0.1pH Accuracy: 0.2pH (at 20) / 0.2pH Battery: 4 x 1.5V Button Battery (Not Included) Product Size: Approx. 3.1 x 1.6 x 15 cm / 1.2 x 0.6 x 5.9 in Weight: Approx. 120g / 4.2oz Operating Steps: 1. Remove the protective cover. 2. Firstly, the electrode of the pH meter should be cleaned with distilled water, and wipe the electrode with filter paper. 3. Turn on the power button located on the battery compartment. 4. Insert the pH meter into the liquid to be measured until the liquid is immersed in the ''immersion line''. If condition allowed, the solution can be immersed slightly above the ''immersion line''. 5. Stir the solution gently and wait for about two minutes, and then read the displayed value. 6. After use, the electrode should be cleaned, turn off the power and put on the protective cover. pH Tester Calibration: 1. Put the pen into the pH6.86 calibration buffer, the height of the buffer solution should not exceed the height of the pen cover, but it must be higher than the electrode. 2. Gently stir the pen in the buffer and let it stand for about 5 seconds. When the reading is stable, stir again and let it stand for about 5 seconds. Repeat several times until the reading is stable and no longer changes. Use a screwdriver to aim the correction button (The small hole on the back), slowly adjust to a reading of 6.86, and then let it stand for about 5 seconds until the reading is stable, that is, the calibration is successful. Note: (Each measurement process needs to be rinsed with tap water). 3. Put the pen into the pH4.0 calibration buffer, the height of the buffer solution should not exceed the height of the pen cover, but it must be higher than the electrode. 4. Gently stir the pen in the buffer and let it stand for about 5 seconds. When the reading is stable, stir again and let it stand for about 5 seconds. Repeat several times until the reading is stable and no longer changes. Use a screwdriver to aim the correction button (The small hole on the back), slowly adjust to a reading of 4.0, and then let it stand for about 5 seconds until the reading is stable, that is, the calibration is successful. pH Tester Maintenance: 1. When there is white crystal on the pen tip, this is normal, don't be nervous, you can soak it in water for a while. 2. Remove the pen cover and turn on the power, it is normal for the digits jumping in the air. 3. Put the pen into the solution to be tested, the height of the solution cannot be higher than the height of the pen cover, but it must be higher than the electrode. 4. Regularly calibrate the PH tester. Generally, it needs to be re-calibrated every three months. 5. After calibration, gently stir the pen in the solution to be tested and let it stand for about 5 seconds. When the reading is stable, stir again and let it stand for about 5 seconds. Repeat several times until the reading is stable and does not change. The reading now is the correct pH. 6. After use, immerse the pen tip electrode in water and wash off the test solution on the electrode. Do not flush the other parts, then cover the pen cover back, and turn off the power. 1 x pH Meter (Battery Not Included) 1 x User Manual 2 x pH Calibration Powder 1 x Screwdriver
  • Fruugo ID: 308239126-690161184
  • EAN: 4841085907022

配送と返品

24時間以内に発送

  • STANDARD: ¥1,049 - 間の配達 月 03 11月 2025–火 11 11月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Shenzhenshidongbangguojimaoyiyouxiangongsi
  • Shenzhenshidongbangguojimaoyiyouxiangongsi
  • longgangqu bantianjiedao banxuegangdadao 3012hao8707-1shi
  • Shenzhen
  • CN
  • 518000
  • kuajingpenyuyan@163.com
  • (+86)075584621615
  • https://www.dbgj.com

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • Johnny Lin
  • EC REP SERVICES SL
  • Calle Gran Via 49, 7 Dch.,MADRID,MADRID,ES
  • Madrid
  • Spain
  • 28013
  • ecrepservice@hotmail.com
  • 34 910563102
  • https://www.OASIS-SERVICE.com