Portable LCD Digital Insulation Resistance Tester Resistance Meter Megameter Electrician Test Instrument

¥56,090
配送料無料

Portable LCD Digital Insulation Resistance Tester Resistance Meter Megameter Electrician Test Instrument

  • ブランド: Unbranded

Portable LCD Digital Insulation Resistance Tester Resistance Meter Megameter Electrician Test Instrument

  • ブランド: Unbranded
希望小売価格: ¥72,890
価格: ¥56,090
得する金額: ¥16,800 (23%)
販売元:
(プレミアムセラー)
¥56,090
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

Portable LCD Digital Insulation Resistance Tester Resistance Meter Megameter Electrician Test Instrument

Feature: 1. The insulation resistance tester is compact, rugged, reliable, and easy to use. 2. Repetitive or hard-to-reach testing is easy with the remote test probe. 3. Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection. 4. CAT IV 600 V overvoltage category rating for added user protection 5. The large backlight display screen make it easy to read measurements. 6. Remote probe, test leads, probes and alligator clips included with each tester 7. With its multiple test voltages, the tester is ideal for many troubleshooting, commissioning, and preventative maintenance applications. Specification: Condition: 100% Brand New Item Type: Insulation Resistance Tester Material: ABS Color: As shown in the picture v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} x\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} x\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} x\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} AC/DC voltage measurement Accuracy Range 600.0 V Resolution 0.1 V 50 Hz to 400 Hz ±(reading % +digits) ±(2% + 3) Input impedance 3 MΩ(nominal), < 100 pF Attenuation common-mode (1 k Ω imbalance) DC > 60 dB, 50 or 60 Hz Overload protection 600 V rms or DC Grounding connection resistance measurement Range/resolution 20.00 Ω 0.01 Ω 200.0 Ω 0.1 Ω 2000 Ω 1.0 Ω 20.00 kΩ 0.01 kΩ Accuracy ±(1.5% + 3) Overload protection 2 V rms or DC Open circuit test voltage > 4.0 V, < 8 V Short-circuit current > 200.0 mA The insulation specification Measurement range 0.01 MΩ to 2000 MΩ Testing voltage 500 V,1000 V Test voltage accuracy + 20%, - 0% Short-circuit current 1 mA(nominal) Self discharge Discharge time < 0.5 seconds, C = 1 µF or less Live circuit indicator Before initializing the test, if the terminal voltage is > 30 V, conduct the suppression test Maximum capacitive load The load can be operated under 1 µF Measurement accuracy 500 V ±(1.5% + 5) 1000 V Below 2000 MΩ ,±(1.5% + 5), Above2000 MΩ, ±(10% + 3) General technical index Maximum voltage applied to any terminal 600 V AC rms or DC Storage temperature -40 °C to 60 °C(-40 °F to 140 °F) Operating temperature -20 °C to 55 °C(-4 °F to 131 °F) Temperature coefficient When temperature < 18 °C or > 28 °C(< 64 °F or > 82 °F), 0.05x (specified accuracy)/°C Relative humidity 10 °C to 30 °C(50 °F to 86 °F), 0% to 95% 30 °C to 40 °C(86 °F to 104 °F), 0% o 75% 40 °C to 55 °C(104 °F to 131 °F), 0% to 40% Vibration Random, 2 g, 5-500 Hz, according to mil-prf-28800f 2 class instrument Impact 1 meter drop as per IEC 61010-1, 2nd version (1 meter drop test, 6 sides, oak floor) Electromagnetic compatibility Accuracy = specified accuracy in a 3 V/M rf magnetic field (EN 61326-1:1997) Security According to ANSI/ISA 82.02.01 (61010-1) 2004, CAN/ csa-c22.2 NO. 61010-1-04, and IEC/EN 61010-1, 2nd version, class IV measurement 600 V (CAT IV) Certificate CSA according to the standard CSA/CAN C22.2 No. 61010.1-04; TUV is in accordance with the standard IEC/EN 61010-1, 2nd version Battery 4 x AA batteries (NEDA 15A or IEC LR6) (not included) Battery life Insulation test purpose At room temperature, the new alkaline battery can perform at least 1,000 insulation tests on the instrument. The results of the standard is in 1000 V through 1 M Ω resistance measured, under the condition of the cycle time for 5 seconds, 25 seconds. Resistance measurement At room temperature, the new alkaline battery can be used for at least 2500 grounding connection insulation measurements. The results of the standard is in the case of 1 Ω resistance measured, the cycle time for 5 seconds, 25 seconds. Size(H x W x L) 5.0 x 10.0 x 20.3 cm /1.97 x 3.94 x 8.00 in Weight 550 g /1.2 lb IP protection grade IP40 Altitude Working altitude 2000 m CAT IV 600 V, 3000 m CAT III 600 V Non-operational (storage) 12000 m Excess capacity 110% range v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} x\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} Package List: 1 x Insulation Resistance Tester2 x TL224 Test Probe2 x Test Line1 x TP74 Test Probe2 x Alligator Clips1 x English Manual Note: 1. Please allow 1-2cm error due to manual measurement. Thanks for your understanding.2. Monitors are not calibrated same, item color displayed in photos may be showing slightly different from the real object. Please take the real one as standard.
  • Fruugo ID: 392384683-839511999
  • EAN: 7590917893992

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Warning: Please read the product instructions carefully before use to ensure correct use.
シリアルナンバー: 7590917893992

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 月 15 12月 2025–月 22 12月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • No. 1-1, Door 57
  • Shihua Village
  • Qingshan District
  • Wuhan
  • CN
  • 430000
  • goldxinks@163.com
  • 0086 17786498762
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795