Description:_x000D_
This digital turbine flow meter has modular design, high accuracy, compact size and stable performance. Easy to replace and maintain internal components. Suitable for use with output modules, sensors and remote transmitters._x000D_
_x000D_
Features:_x000D_
_x000D_
Modular design makes it suitable for use with output modules, sensors and remote transmitters. _x000D_
Compact structure, easy to install. _x000D_
Intuitive clear reading, high reliability, measuring accuracy is 1%. _x000D_
High-definition displays show both instantaneous and cumulative flow. _x000D_
Can be widely used to measure diesel, kerosene, gasoline, etc. _x000D_
_x000D_
Specification:_x000D_
Material: Aluminum alloy_x000D_
Operating voltage: 2.3-3.3V_x000D_
Battery type: 2 x AAA LRO3 batteries_x000D_
Connection size: 1.5inch NPT_x000D_
Repetition: 0.5%_x000D_
Measure accuracy: 1%_x000D_
Maximum working pressure: 20BAR_x000D_
Flow range: 15-120L / Min_x000D_
Single count: 0.00-9999.9_x000D_
Total cumulative count: 0-99999_x000D_
Mistakes count: 0.1000-9.9999_x000D_
Working temperature: -10C~ +60C(14F~140F)_x000D_
Standby time: 1 year_x000D_
Application: Diesel, kerosene, gasoline_x000D_
Color: Blue_x000D_
Weight: 684g_x000D_
_x000D_
Malfunction and solution:_x000D_
The flow meter is not accurate. 1. The method of field calibration is not correct. Calibrate again. _x000D_
2. The flow rate on the meter is below the lowest. Increase the flow rate. _x000D_
3. The flow meter is blocked by the dry liquid. Take out the impeller and clean it carefully and make sure the impeller turns freely. _x000D_
4. The impeller is wrapped by the sealing material. Remove the meter and make sure the impeller turns freely. _x000D_
5. Too close to the impeller. Install properly _x000D_
6. Too close to the motor or electronic noise environment Install properly _x000D_
The reading numbers faded or blanked out. 1.Battery is exhausted or not connected Check the batteries or even replace them _x000D_
Flow rate is normal but the meter can not count. Press the button of DISPLAY, the meter start. 1. Field calibration is not correct. Calibrate again. _x000D_
2. The impeller is blocked or damaged. Remove the meter and make sure the impeller turns freely. _x000D_
3.The impeller is wrapped by the sealing material. Remove the meter and make sure the impeller turns freely. _x000D_
Flow rate is low and the meter can not count. Press the button of DISPLAY, the meter start. 1. The flow meter is blocked by the dry liquid. Take out the impeller, clean it carefully and make sure the impeller turns freely. _x000D_
2. The flow rate on the meter is below the lowest. Increase the flow rate. _x000D_
The meter can not calibrate. 1. Circuit board is break down. Replace the circuit board. _x000D_
2. Button is fail to press. Replace the circuit board. _x000D_
_x000D_
_x000D_
Package List:_x000D_
1 x Turbine Flow meter
-