Repeater Industrial Grade Photoelectric Isolation 4?Channel RS485 Hub Sharer Splitter

¥6,490
+ 配送料¥2,149

Repeater Industrial Grade Photoelectric Isolation 4?Channel RS485 Hub Sharer Splitter

  • ブランド: Unbranded

Repeater Industrial Grade Photoelectric Isolation 4?Channel RS485 Hub Sharer Splitter

  • ブランド: Unbranded
希望小売価格: ¥12,990
価格: ¥6,490
得する金額: ¥6,500 (50%)
販売元:
¥6,490
+ 配送料¥2,149

在庫あり

以下の支払い方法を利用することができます

説明

Item Type: Repeater _x000D_ Compatibility: Compatible with RS-232, RS-485TIA/EIA standards_x000D_ Working Voltage: DC: 9-24V_x000D_ Rated Power: 0.5-1.2W_x000D_ Input Interface: 1 RS-232/1 RS-485_x000D_ Output Interface: 4 RS-485_x000D_ Load Capacity: 128 nodes per interface_x000D_ Communication Distance: 2500 meters shielded wire or twisted pair wire per interface_x000D_ Communication Rate: 300bps-115.2Kbps_x000D_ Installation Method: 35mm rail installation, 4-hole installation on the back plate_x000D_ Structure Size: Approx. 115 x 90 x 40mm / 4.5 x 3.5 x 1.6in_x000D_ Working Environment: -30 to 70 relative humidity>95%RH_x000D_ Wiring Notes: _x000D_ 1. 485 communication line must use shielded twisted pair, preferably multiple strands for spare, the longest is not more than 2500 meters._x000D_ 2. The wiring should be as far away as possible from high-voltage wires, not parallel to power lines, and not to be bundled together._x000D_ 3. 485 bus must be a hand-in-hand bus structure, and resolutely eliminate star connection and bifurcation connection._x000D_ 4. If there are more than 30 controllers or the cable length is greater than 500 meters, it is recommended to use a 485 repeater._x000D_ 5. The AC-powered equipment and the chassis must be grounded and well grounded._x000D_ 6. Connect the GND ground of all 485 devices with shielded wires._x000D_ Requirements For Wire Selection Using RS-485 Bus For Communication: _x000D_ Use 2-core shielded twisted pair cable_x000D_ Copper, wire diameter 0.50.75 square millimeter,_x000D_ Impedance 3888/km,_x000D_ Capacitive resistance 3050nF/km,_x000D_ 2-core shielded twisted-pair cable with a twisting distance of 20 mm (if the line distance is not more than 500 meters, the line standard can be appropriately reduced, but it must be a twisted pair)_x000D_ Signal Common Ground: _x000D_ 1. All devices on the same network segment must have a unified signal ground to avoid common mode interference._x000D_ 2. For centralized power supply, directly connect the DC negative poles of all power supplies on the same network segment (including the self-contained power supplies of communication equipment) to form a common signal ground._x000D_ At this time, the signal ground is the DC power ground._x000D_ 3. When a single home supplies power independently, connect the ground (black wire) pins of all bus devices on the same network segment together to form a common signal ground.
  • ブランド: Unbranded
  • カテゴリー: 分配器
  • Fruugo ID: 314451776-701042057
  • EAN: 4523235896812

配送と返品

3日間以内に発送

  • STANDARD: ¥2,149 - 間の配達 月 13 10月 2025–月 20 10月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • 91440300MA5HDL2A4K
  • SHEN ZHEN SHI LAI LI ZHU BAO SHI PIN MAO YI YOU XIAN GONG SI
  • Room B, 21F, Block A, Jingang Huating, 4009 Baoan Avenue, Yantian Community, Xixiang Street, Baoan District, Shenzhen
  • Shenzhen
  • CN
  • 518102
  • 939301410@qq.com
  • 15600000000

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • 951000000
  • MJCM SARL
  • 78 avenue des Champs Elysees Bureau 326, 75008 Paris, France
  • Paris
  • FR
  • 75008
  • mjcm190928@gmail.com
  • 0033 767213611