Primary Coil Easy To Use Portable Physics Teaching Tool Electromagnetic Induction Solenoid PVC+Brass for Laboratory for School hwy

¥5,390
+ 配送料¥1,149

Primary Coil Easy To Use Portable Physics Teaching Tool Electromagnetic Induction Solenoid PVC+Brass for Laboratory for School hwy

  • ブランド: Unbranded

Primary Coil Easy To Use Portable Physics Teaching Tool Electromagnetic Induction Solenoid PVC+Brass for Laboratory for School hwy

  • ブランド: Unbranded
価格: ¥5,390
販売元:
¥5,390
+ 配送料¥1,149

在庫あり

以下の支払い方法を利用することができます

説明

Primary Secondary Coil Electromagnetic Induction Coil Experiment Instrument for Physics Teaching Feature: 1. Lightweight and portable, the electromagnetic induction spiral coil specializes in electromagnetic induction phenomena, which is convenient to carry and use. 2. Easy to use, it can be used with bar magnets, ammeters, sliding varistors and other instruments. 3. Physics laboratory equipment auxiliary tools make physics experiment learning more efficient. 4. Rugged and , constructed of enameled copper, wear resistant, not easy to be damaged, and long service life. 5. It is designed to demonstrate electromagnetic induction and verify Lenz's law for students. It is an ideal choice for physics teaching. Specification: Item Type: Electromagnetic Induction Coil Material: PVC+Brass Purpose: Middle and high school physics experiment Applicable Experiments: Study electromagnetic induction, verify Lenz's law, study magnetic induction The outer diameter of the hole at the bottom of the original coil is: Approx. 221mm / 0.90.04in The inner diameter of the hole at the bottom of the original coil is: Approx. 130.5mm / 0.50.02in The height of the round hole at the bottom of the original coil: Approx. 60mm / 2.4in The diameter of the hole at the bottom of the secondary coil is: Approx. 351mm / 1.40.04in The inner diameter of the circular hole at the bottom of the secondary coil is: Approx. 491mm / 1.90.04in The height of the round hole at the bottom of the secondary coil: Approx. 80mm / 3.1in Soft Length: Approx. 85mm / 3.3in How to use: 1. Study the of electromagnetic induction: connect the two ends of the secondary coil B to the two terminals of the ammeter with wires; When using one end of the bar magnet to quickly insert (or withdraw) the secondary coil, the pointers of the galvanometer are all deflected, indicating that there is an induced current in the secondary coil at this time. This is called electromagnetic induction. On the contrary, if the magnet is fixed, the movement of the auxiliary coil will also produce the same 2. Verify Lenz's Law (1) Experimental method: Observe the change in the direction of current indicated in the galvanometer when the magnet is inserted or withdrawn, and when the polarity of the magnet changes; (2) Connect the original coil to a 3-4V DC power supply, and put a single?pole switch and a 109 sliding rheostat in series in the circuit. The same occurs when the original coil is used instead of the magnet to do the above experiment. Changing the direction of current flowing into the primary coil will change the direction of induced current in the secondary coil. (3) According to the device in picture(2), first insert the primary coil into the secondary coil, and then energize the primary coil. When the switch is just turned on or just cut off, the magnetic flux passing through the secondary line diagram changes, which also occurs at this time. The current is induced, and the direction of the current is opposite. Change the direction of the current flowing into the primary coil and redo this experiment, the direction of the induced current in the secondary coil will also change. (4) According to the device in picture (2), insert the primary coil into the secondary coil and connect the circuit, and then use the sliding rheostat to quickly change the current through the primary coil (increase or decrease), and the secondary coil will also be Generate an induced current, and the direction of the induced current is the same as picture (3). Synthesize the above experimental results and analyze it to verify Lenz's law. 3. Study the of magnetic induction Put the primary coil in the above picture 2 device into the secondary coil and wait for it to stand still. There is no induced current in the secondary coil. At this time, insert or withdraw the soft iron C into or out of the central hole of the primary coil, the soft iron is magnetized, and the magnetic field Increase or decrease. The change in the magnetic flux in the secondary coil also generates induced current. This experiment can explain both the magnetic induction and electromagnetic induction phenomena. During the experiments in the device picture (2), insert the soft iron into the center hole of the original line diagram for demonstration, and the induced current in the secondary coil will increase the effect more obviously. Package List: 1 x Primary Coil A 1 x Secondary Coil B
  • Fruugo ID: 404103955-857697333
  • EAN: 3694560095360

配送と返品

24時間以内に発送

  • STANDARD: ¥1,149 - 間の配達 月 27 10月 2025–月 03 11月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Shenzhenyuandedianziyuouxiangongsi
  • Shenzhenyuandedianziyuouxiangongsi
  • Room 1401-04 Yousuo Bldg 2000
  • Jiaxian Road Gangtou Community
  • Bantian Subdistrict
  • Shenzhen
  • China
  • 518500
  • szrhkj41@163.com
  • 15819859068

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • Huang Pengliang
  • FORCHAIN GmbH
  • Vilbeler Landstra?e73 60388 Frankfurt am Main
  • Frankfurt am Main
  • Frankfurt am Main
  • DE
  • 60388
  • nnicolesusan093@gmail.com
  • 1638127736