Item Type: Single Phase Meter_x000D_
Product Material: Pure copper + plastic_x000D_
Voltage: 230V AC_x000D_
Current: 5 (80) A_x000D_
Power: 800imp/kwh 50Hz_x000D_
Insulation Performance: AC voltage 4kv for 1 minute, 1.2 / 50us waveform pulse voltage 6kv_x000D_
Product Description: _x000D_
DDS1891 single-phase electronic DIN track active energy meter is a new type of single-phase two-wire active energy meter, which uses microelectronics technology, and introduces large-scale integrated circuits, and uses advanced digital technology and SMT technology. Its completely independent intellectual property rights and minimum size._x000D_
The meter fully complies with the relevant technical requirements of the class 1 single-phase active meter specified by the international standard IEC62053-21. It can accurately and directly measure 50Hz or 60Hz active power consumption from a single-phase AC grid, and can display the total power consumption through the stepper motor type pulse register._x000D_
It has the characteristics of good reliability, small size, light weight, beautiful appearance and convenient installation._x000D_
Functions And Features: _x000D_
1.35mm standard DIN rail installation, in line with standard DIN EN50022._x000D_
2. Unipolar width (modulus 18mm), in line with standard DIN43880._x000D_
3. Display the standard configuration 5 + 1 number (99999.1kWh) through the stepper motor type pulse register._x000D_
4. Standard configuration of passive pulse output (polarity), long-distance pulse output passive (polarity) can be selected. And easily contact with various AMR systems, in line with standards IEC 62053-31 and DIN 43864._x000D_
5. When the meter starts measuring, the pulse indicator flashes._x000D_
6. One-way measurement of single-phase two-wire active power, independent of the direction of the load current trend. Comply with standard IEC 62053-21._x000D_
7. Standard configuration S type connection, U type connection can be selected._x000D_
8. Extend the terminal cover to protect the safety of use. State (green) and energy pulse signal (red)._x000D_
9. Directional measurement of AC active power consumption. The direction in which the load current flows does not matter. Comply with standard IEC 62053-21._x000D_
10. Direct connection operation, two types of wiring can be selected. The standard configuration is S-type wiring, but U-type wiring is possible._x000D_
11. Extend the terminal cover to protect the safety of use_x000D_
_x000D_
Size: Approx. 88mm / 3.5in_x000D_
63mm / 2.5in_x000D_
75mm / 3in_x000D_
_x000D_
44mm / 1.7in_x000D_
45mm / 1.8in_x000D_
68mm / 2.7in_x000D_
_x000D_
35.5mm / 1.4in_x000D_
5mm / 0.2in
-