Two-way DC 32-function wide voltage relay module, water pump motor control.

¥4,599
+ 配送料¥899

Two-way DC 32-function wide voltage relay module, water pump motor control.

  • ブランド: Unbranded

Two-way DC 32-function wide voltage relay module, water pump motor control.

  • ブランド: Unbranded
希望小売価格: ¥9,190
価格: ¥4,599
得する金額: ¥4,591 (49%)
販売元:
¥4,599
+ 配送料¥899

在庫あり

以下の支払い方法を利用することができます

説明

Feature: Various functions: 32 common functions, pulse trigger, power failure, cycle timing, etc., to meet more application needs. The relay corresponds to a passive contact switch, which controls the on and off of a line, which is simple and convenient to use. High compatibility: wide voltage working mode, 7v30v universal voltage, and support for DC. The output power can be controlled within 5A DC or AC load, adjustable at any time from 0.01 seconds to 999 minutes. Wide range of applications: can be used to control solenoid valves, water pumps, motors, light strips, etc. Specification: Item Type: Relay Module Product Model: YF-7 Input Voltage: DC 7~30V Optional Output Power: Control DC or AC load within 5A Time Range: 0.01 Seconds to 999 Minutes, Optional Time Adjustable Description of cable connection port: +: Input power Positive-: Input power NegativeIn+: Positive Signal Input TerminalIn-: Negative Signal Input TerminalNO: Relay's Normally Open Interface, The Relay is Off Before It Closes, and It is Short-Circuited to COM After It Closes.COM: Relay's Common InterfaceNC: Relay's Normally Closed Interface, Short Circuit with COM Before Relay Closes, and Hangs in the Air After ClosingP-23: When the signal disappears for more than A seconds, the relay pulls in, the signal disappears, and the relay stopsP-24: There is a signal. After A seconds, the relay closes. After the signal disappears for more than A seconds, the relay stops.P-25: There is a signal. After A seconds, the relay closes. When there is another signal for more than A seconds, the relay stops.P-26: When there is a signal, the relay stops after closing for A seconds, and when the signal disappears, the relay stops after closing again for A seconds.P-27: If there is a pulse signal, the relay stops; if there is no pulse signal, the relay closes for A seconds; (the signal continues or the signal disappears will be regarded as no pulse signal)P-28: After power-on, after a delay of A seconds, the relay closes until the power is turned offP-31: After power-on, the relay closes for A seconds, disconnects for B seconds, infinite loop; shutdown stopsP-32: When there is a signal, start P-31 infinite loop; when the signal disappears, end the loopP-33: Give a signal to start P-31 infinite loop; give another signal to end the loopP-34: After power-on, the relay closes after a delay of A seconds and stops after closing for B secondsP-35: There is a signal, after a delay of A seconds, the relay closes, and the relay closes after closing for B seconds.P-36: When there is a signal, after A seconds, the relay closes, and after B seconds, the relay stops, the signal disappears, and the timer is cleared and stopped.P-37: If there is a signal, the relay automatically stops for A seconds when the relay is closed, and then it counts for B seconds after it stops. The signal trigger is invalid within the time A+B.P-38: When there is a signal, the relay automatically stops when it is closed for A seconds, and after stopping and counting for B seconds, it automatically stops when it is closed again for A seconds.P-41: No action when there is a signal; trigger when the signal disappears; the relay disconnects after a delay of A timeP-42: The signal disappears, after delaying time A, the relay works; working time B endsP-43: The signal disappears. After time A is exceeded, the relay works; working time B endsP-44: After giving the signal more than A times, the relay closes for B seconds and stopsP-45: After power-on, relay 1 will work for A seconds and then disconnect; Relay 2 will work for B seconds and disconnectP-46: Give signal 1, after relay 1 works for A seconds and disconnects; relay 2 works for B seconds and disconnectsP-47: Give signal 1, after relay 1 works for A seconds; relay 2 starts to work; after B seconds, relays 1, 2 disconnect at the same timeP-48: After power-on, relay 1 works for A seconds and then disconnects; stops for B seconds; re
  • Fruugo ID: 414252742-875193883
  • EAN: 6901587101750

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Not suitable for children under 36 months
材料: Plastic 5%

配送と返品

24時間以内に発送

  • STANDARD: ¥899 - 間の配達 金 24 10月 2025–月 03 11月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • YQ Trading A
  • Guangzhou Yueqing Trading Co., Ltd.
  • 34 Xi San Jie, Changban
  • Room 401, Tianhe District
  • Guangzhou
  • CN
  • 510000
  • yueqtrad@outlook.com
  • 8613559392222

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • IBERTRUST GLOBAL SOCIEDAD LIMITADA
  • IBERTRUST GLOBAL SOCIEDAD LIMITADA
  • C/ PABLO IGLESIAS 1A ENTRES
  • CASTELLON DE LA PLANA
  • ES
  • 12001
  • contact@ibertrust.info
  • 0034 611904867