DC Voltage Current Power Energy Consumption Meter Communication Module for Certain Brand

¥8,290
配送料無料

DC Voltage Current Power Energy Consumption Meter Communication Module for Certain Brand

  • ブランド: Unbranded

DC Voltage Current Power Energy Consumption Meter Communication Module for Certain Brand

  • ブランド: Unbranded
価格: ¥8,290
販売元:
¥8,290
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

DC Voltage Current Power Energy Consumption Meter Communication Module for Certain Brand

This module is mainly used for measuring DC voltage, current, active power, frequency and energy consumption, the module is without display function, the data is read through the RS485 interface._x000D_ _x000D_ Features:_x000D_ _x000D_ It is mainly used for measuring DC voltage, current, active power, frequency and energy consumption. _x000D_ The current measure range is 50A, 100A, 200A, 300A depend on the external shunt specification. _x000D_ There are 10 different kits to choose, enough to meet your various need. _x000D_ Physical layer use UART to RS485 communication interface, baud rate is 9600, 8 data bits, 2 stop bit, no parity. _x000D_ The application layer use the ModbusRTU protocol to communicate, it only supports function codes such as 0x03, 0x04,0x06, 0x41, 0x42, etc. _x000D_ Voltage threshold can be set, divide into high voltage and low voltage threshold, when the measured voltage exceeds the threshold, it can alarm. _x000D_ _x000D_ Specification:_x000D_ Brand: PEACEFAIR_x000D_ Model: PZEM-017_x000D_ Voltage:_x000D_ _x000D_ Measuring Range: 0.05-300V (When the test voltage is 7V, please use the independent power supply mode) _x000D_ Resolution: 0.01V _x000D_ Measurement Accuracy: 1% _x000D_ Current:_x000D_ _x000D_ Measuring Range: 0.02-300A (Can be matched with 50A, 100A, 200A, 300A four kinds of shunt) _x000D_ Resolution: 0.01A _x000D_ Measurement Accuracy: 1% _x000D_ Power:_x000D_ _x000D_ Measuring Range: 0.2-90kW _x000D_ Resolution: 0.1W _x000D_ Measurement Accuracy: 1% _x000D_ Energy Consumption:_x000D_ _x000D_ Measuring Range: 0-9999kWh _x000D_ Resolution: 1Wh _x000D_ Measurement Accuracy: 1% _x000D_ Reset Energy: Use Software to Reset_x000D_ Over Voltage Alarm:_x000D_ _x000D_ Default High Voltage Threshold: 300V _x000D_ Default Low Voltage Threshold: 7V _x000D_ Communication Interface: RS485 Interface_x000D_ Working Temperature: -20~60_x000D_ Product Size: Approx. 9*6*2.3cm/3.5*2.4*0.9inch_x000D_ Weight: Approx. 77g~287g / 2.7oz~10.1oz_x000D_ Register address Description Resolution _x000D_ 0x0000 Voltage value 1LSB correspond to 0.01V _x000D_ 0x0001 Current value 1LSB correspond to 0.01A _x000D_ 0x0002 Power value low 16 bits 1LSB correspond to 0.1W _x000D_ 0x0003 Power value high 16 bits _x000D_ 0x0004 Energy value low 16 bits 1LSB correspond to 1Wh _x000D_ 0x0005 Energy value high 16 bits _x000D_ 0x0006 High voltage alarm status 0xFFFF is alarm,0x0000 is not alarm _x000D_ 0x0007 Low voltage alarm status 0xFFFF is alarm,0x0000 is not alarm _x000D_ _x000D_ _x000D_ _x000D_ Register address Description Resolution _x000D_ 0x0000 High voltage alarm threshold(5~350V),_x000D_ default is 300V 1LSB correspond to 0.01V _x000D_ 0x0001 Low voltage alarm threshold1~350V,_x000D_ default is 7V 1LSB correspond to 0.01V _x000D_ 0x0002 Modbus-RTU address The range is _x000D_ 0x0001~0x00F7 _x000D_ 0x0003 The current range 0x0000: 100A_x000D_ 0x0001: 50A_x000D_ 0x0002: 200A_x000D_ 0x0003: 300A _x000D_ _x000D_ _x000D_ _x000D_ Optional Kit _x000D_ #1 1 x DC Consumption Meter _x000D_ #2 1 x DC Consumption Meter_x000D_ 1 x RS485 to USB Cable _x000D_ #3 1 x DC Consumption Meter_x000D_ 1 x 50A Shunt _x000D_ #4 1 x DC Consumption Meter_x000D_ 1 x 100A Shunt _x000D_ #5 1 x DC Consumption Meter_x000D_ 1 x 200A Shunt _x000D_ #6 1 x DC Consumption Meter_x000D_ 1 x 300A Shunt _x000D_ #7 1 x DC Consumption Meter_x000D_ 1 x RS485 to USB Cable_x000D_ 1 x 50A Shunt _x000D_ #8 1 x DC Consumption Meter_x000D_ 1 x RS485 to USB Cable_x000D_ 1 x 100A Shunt _x000D_ #9 1 x DC Consumption Meter_x000D_ 1 x RS485 to USB Cable_x000D_ 1 x 200A Shunt _x000D_ #10 1 x DC Consumption Meter_x000D_ 1 x RS485 to USB Cable_x000D_ 1 x 300A Shunt _x000D_ _x000D_ Note:_x000D_ _x000D_ RS485 interface is passive output, need external connect 5V power supply and the external power supply should 100mA. _x000D_ When the input test voltage is less than 7V, it must supply 5V independent work voltage through USB port. _x000D_ Do NOT use the USB port bring by your PC to be the independent power supply, otherwise it may damage your PC.
  • Fruugo ID: 391455541-838022800
  • EAN: 5442636687999

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

安全上の警告: Do not let your children touch this product alone to avoid swallowing or other injuries

配送と返品

24時間以内に発送

  • STANDARD: 無料 - 間の配達 月 15 12月 2025–月 22 12月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Shengwen43
  • Shenzhen Jinghao Industrial Co., Ltd.
  • No. 102, No. 7, East Sixth Lane, Ma'antang Community, Bantian Street, Longgang District, Shenzhen
  • Shenzhen
  • China
  • 515100
  • MarciaMckinneyMar@outlook.com
  • 15507547151

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • Nolan Dax
  • HUMISS TRADING S.L
  • Calle Luis Bunuel 12-3A
  • Madrid
  • Spain
  • 28018
  • Nolandax0909@gmail.com
  • 34613177772