Current Detection Sensor Module Digital Display 4‑20mA Relay Component DC 12V

¥4,349
配送料無料

Current Detection Sensor Module Digital Display 4‑20mA Relay Component DC 12V

  • ブランド: Unbranded

Current Detection Sensor Module Digital Display 4‑20mA Relay Component DC 12V

  • ブランド: Unbranded
希望小売価格: ¥4,799
価格: ¥4,349
得する金額: ¥450 (9%)
販売元:
¥4,349
配送料無料

在庫はあと5個のみ

14日間返品ポリシー

以下の支払い方法を利用することができます

説明

Current Detection Sensor Module Digital Display 4‑20mA Relay Component DC 12V

Features 1.Composed of professional PCB materials, stable performance and long service life. 2.Increase the power supply anti‑reverse protection to reduce the risks of work errors and improve work efficiency. 3.With three‑digit display, three‑button adjustment is convenient and easy to use. 4.The module with small size, easy to carry and store, convenient to use and with good performance. 5.Great workmanship, with strict quality control and quality assurance, high safety factor, can be used with peace of mind. Specification Item Type: Current Detection Sensor Module Material: PCB Working Current: Standby: 12mA, Working: 56mA Working Voltage: DC12V Digital Display Life: ≥50,000 hours Relay Life: ≤100,000 times Digital Tube: 3 in 1 Working Temperature: -20℃~75℃ Measuring Range: 0-25mA Detection Signal: 4-20ma Product Features: 4-20ma Current Detection: After the module is powered on, the PX is initially displayed and the currently set mode is displayed. At this time, the mode can be adjusted by pressing the "+" and "-" buttons. It will enter the real-time display of the measured current after 4s. Three buttons to set the upper and lower limits and function mode selection Interface Description: Input Positive Pole: Connect to the positive pole of the power supply Negative Pole: Connect to the negative pole of the power supply AO: 4-20ma signal input COM: It is connected to the negative pole of the power supply Output NO: NO end COM: Public NC: NC end Several Modes Can be Set as Follows: (Long press "-" for 3s to enter the adjustment mode) P-1: Suction exceeds the set value, but is disconnected below the set value; the measured value exceeds the lower limit value and the relay suctions, and disconnects below the lower limit value. P-2: Disconnect when the value exceeds the set value, but is lower than the suction; when the measured value exceeds the lower limit, the relay is disconnected, and the suction is lower than the lower limit. P-3: Suction in the interval and disconnected outside the interval; the measured value is between the upper limit and the lower limit and the relay sucks, otherwise it is disconnected P-4: Disconnected in the interval, sucked outside the interval; the relay is disconnected between the upper limit and lower limit of the measured value, otherwise sucked P-5: Disconnect below the lower limit, and absorb above the upper limit; when the measured value exceeds the lower limit, the relay will disconnect, and the relay will absorb above the upper limit. P-6: Suction is lower than the lower limit, and it is disconnected above the upper limit; the measured value exceeds the lower limit and the relay is suctioned, and the relay is disconnected above the upper limit. Setting Instructions (for The Convenience Of Description, Use K1 For The setting key, K2 for the + key, and K3 for the-key): Key Description: "K1 shift/adjust; K2+; K3-/mode selection Press the K1 key, the first digit flashes, adjust the lower limit of hundreds, press K2, K3 to adjust 0~1 change Press the K1 button, the second digit will flash, adjust the tens digit of the lower limit, press K2, K3 to adjust 0-9 changes Press K1 key, the third lower third digit flashes, adjust the lower limit one digit, press K2, K3 to adjust 0-9 change Press the K1 key, the 4th, lower, and fourth digits will flash, adjust the upper limit of hundreds, press K2, K3 to adjust 0~1 changes Press K1 key, the 5th bottom fifth digit flashes, adjust the upper limit ten digits, press K2, K3 to adjust 0-9 changes Press K1 key, the 6th, lower and sixth digits will flash, adjust the upper limit one digit, press K2, K3 to adjust 0-9 changes Press the K1 key for the 7th time, the digital tube is not flashing, it displays the measured current value Package List 1 x Current Detection Sensor Module
  • Fruugo ID: 271671896-602233680
  • EAN: 9140150437835

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 月 29 12月 2025–金 02 1月 2026 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る