説明
Occupied/Unoccupied,Report Mode:Report When State Changes,Unoccupied To Occupied,Report Within 0.5s,Occupied To Unoccupied,Output Unoccupied State In 40s;Occupied Stationary/Occupied Active,Report Mode:Report When State Changes,Switch Between Stationary And Active,Report Within 0.5s;Human Body Distance Active,Report Mode:Output Data Once In 2s,Distance Unit:Cm,Distance Range:0-65535cm;Body Movement Amplitude Parameter 0-100,Report Mode:Output Data Once In 1 Sec,Distance Range:0-65535cm
Body Movement Amplitude Parameter 0-100,Report Mode:Output Data Once In 1 Sec;Distance Unit:Cm,Distance Range:0-65535cm;Body Movement Amplitude Parameter 0-100,Report Mode:Output Data Once Every 1 Second.Human Body Orientation Active Reporting,Reporting Mode:2 Seconds To Output Data,6byte,Each 2byte Represents A Direction (X,Y,Z),Unit:Cm,Orientation Information Has Positive And Negative,Each Direction Of The 2byte16 Hexadecimal Data Is Converted To Binary Data 16-Bit Data
The First 0 Means Negative,The First 1 Means Positive,The Remaining 15Bits In Accordance With The High Position In The First Converted To Decimal,That Is,To Get The Specific Coordinates.The First Bit Is 0 For Negative,The First Bit Is 1 For Positive,And The Remaining 15 Bits Are Converted To Decimal Before The High Bit To Get The Specific Coordinate Value;Heartbeat Value,Reporting Mode:3s Output Data Once,Value Range:50-120
Heart Rate Waveform,Reporting Mode:1s Output Data Once,Reporting Mode:1s Output Data Once,5 Bytes The 5 Values In 1s In Real Time,Which Is The Real Value +128 (To Let The Display Of The Curve As A Whole Is In The Middle Of The Coordinate Axis,For A Better Display Experience);Respiration Value. Reporting :Output Data Once In 3s.Respiratory Information, Reporting Mode: Report When The State Changes
Respiratory Waveform,Reporting Mode:Output Data Once In 1s; Bed In/Bed Out, Reporting Mode:Report When The State Changes;Sleep State(Awake/Light Sleep/Deep Sleep),Reporting Mode:Output Data Once In 10min Under The Bed In State.Awake Time/Light /Deep ,Reporting :Under The Bed State,Output The Latest Data Of The Corresponding Time Following The Sleep State Of 10min
Sleep Quality Score,Report The Score Of The Sleep Segment At Of The Sleep Process,With The Score Ranging From 0 To 100;Report The Comprehensive Sleep State,Reporting :Once Every 10 Minutes;Report The Sleep Quality Analysis,Reporting :Report The Whole Night'S Sleep Quality At Of The Sleep Process When The Sleep Process Is Judged To Be Over.Sleep Quality Analysis Is Reported In The Following Way:When The Sleep Process Is Judged To Be Over,The Sleep Statistics Of The Whole Night Are Reported
Sleep Abnormality Report,Abnormal Struggle Report,Unoccupied Time Report,Sleep Quality Rating Report,Report Mode:Report When The State Changes
Type:Module
Notes:
1. GP1-GP4 Are Parameter Selection Control Terminals,Which Can Be Redefined According To User's Requirement
2. The Output Signals Of This Interface Are All 3.3VTTL Level
Tools Preparation
1. Ttl Serial Tool, Cable,Pc,Serial Assistant Terminal
2. Radar-EVB Demo Board(Default Graffiti Platform,Free To Adapt Their Own Communication Modules)
3. Radar User Manual(Protocol)
Different Batches May Have Differences In Product Appearance,Color,And Printed Characters,Which Will Not Affect The Use
Colour:Green
Material:PCB
Size:3.5x3cm
Package Contents:
1 * Module
Only the above package content, other products are not included.
Note: Light reflection and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.
-
Fruugo ID:
325165434-720209241
-
EAN:
9347009409351