70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

¥4,499
+ 配送料¥1,499

70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

  • ブランド: Unbranded

70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

  • ブランド: Unbranded
希望小売価格: ¥8,990
価格: ¥4,499
得する金額: ¥4,491 (49%)
販売元:
¥4,499
+ 配送料¥1,499

在庫あり

以下の支払い方法を利用することができます

説明

Item Type: Blood Oxygen Probe Material: Plastic Applicable for CSI models, others are not applicable Specification: LED 660nm/905nm/940nm Maximum Output Power: 15 mw Suitable for Adults with a weight >40kg, clamped on the index finger or any finger. Spo2 Test Range: 70%~100% Spo2 Test Accuracy: 2% when 90%~100%, 3% when 70%~89% Pulse Rate Test Range: 30~245 bpm Pulse Rate Test Accuracy: 3 bpm Main Structure: Consists of plug, cable and probe Application: Used for pulse oximeters and multi-parameter monitors to continuously and non-invasively collect and transmit the pulse and oxygen saturation signals of patients (adults with a body weight >40kg); not suitable for weak perfusion and exercise conditions Monitoring, the probe is not suitable for long-term monitoring, it should be checked every 4 hours or measured with 2 fingers. Contraindications: Do not fix this product in a location where the patient has tissue damage; it is not suitable for patients and users who are allergic to PVC, TPU, TPE, ABS plastics. Warning: A) Improper use will cause inaccurate measurement. B) When the light is too strong, the measurement will be inaccurate. In some cases, a piece of opaque material should be used to shade the light around the sensor. C) The blood oxygen saturation probe should be moved to a new location at least every 4 hours. Because local skin conditions will affect the ability of the skin to withstand the placement of the probe, it is necessary to change the position of the sensor frequently according to the conditions of some patients. If the integrity of the skin changes, the probe needs to be moved to another location. D) Dye in the blood vessel will cause inaccurate measurement. E) The performance of the probe is easily affected by activities, so it is not suitable for active patients. F) Do not use straps to fix the probe or tie it to death, because venous pulsation will cause inaccurate saturation measurement. G) Like other armarium, cables should be placed so as not to entangle or suffocate the patient. H) Do not use during MRI scan. Because the conductor current will cause burns. Moreover, the blood oxygen saturation probe will affect the MRI image, and the MRI device will also affect the accuracy of the blood oxygen measurement. I) Do not change or modify this product at will. Because this will affect its performance or accuracy. J) Do not use radiation, steam or ethylene oxide for degassing. K) Do not immerse the product in liquid for cleaning and degassing. L) Mobile phones or mobile RF communication equipment will affect the operation of this sensor. How to Use: 1) Place your index finger on the sensor window of the pulse oximetry probe, and touch the stop button at the end of your finger. 2) If the nail is too long, it will affect the fingertip to touch the stop button. 3) Open the lower cover of the finger clamp of the sensor to apply even force to the entire length of the gasket. Check the location of the sensor. If the index finger is placed incorrectly or cannot be used, you can use other fingers or use other types of oxygen sensors. Do not use the pulse oximetry probe on childrens thumbs or toes, or on the entire hands and feet. Note: When selecting the sensor placement site, priority should be given to the limb site without arterial catheter, blood pressure cuff and venous infusion tube. 4) When placing the sensor, route the cable along the back of the hand. 5) Connect the pulse oximetry probe to the oximeter and check whether the operating procedure complies with the steps described in the operating manual. Note: If the sensor cannot accurately monitor the pulse beating, it means that its position is improper or its place is too thick, too thin, or too pigmented to achieve proper light transmission. If the above situation occurs, reposition the sensor or select another type of sensor. Maintenance, Cleaning, Disinfection And Sterilization: A) Check whether the product is undamaged and clean before use. B) Cleaning: Use mild detergent or soap solution to soak a warm cloth when cleaning. The product should be dried thoroughly after cleaning. C) Disinfection: Use chemical disinfectants, such as ethanol, propanol or phenol disinfectants. Note: Do not immerse the product in liquid. Don't be exposed to strong ultraviolet radiation. D) Sterilization: Sterilize with ethylene oxide gas (Et0) at the maximum temperature of 50C/122F, and then perform necessary ventilation according to the sterilizer manufacturer's recommendations. Use Period: It is recommended to replace it every 6 months of use. If you still need to use it, please evaluate it and strictly inspect it during use. Storage Method: After cleaning, disinfecting and drying the product, put it in a sealed plastic bag The Surrounding Environment Should Meet the Following Conditions: Temper
  • Fruugo ID: 394226838-842662726
  • EAN: 7420873863886

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

安全上の警告: Do not suitable for children under 36 months.

配送と返品

3日間以内に発送

  • STANDARD: ¥1,499 - 間の配達 火 07 10月 2025–火 14 10月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • 91440300MA5HDL2A4K
  • SHEN ZHEN SHI LAI LI ZHU BAO SHI PIN MAO YI YOU XIAN GONG SI
  • Room B, 21F, Block A, Jingang Huating, 4009 Baoan Avenue, Yantian Community, Xixiang Street, Baoan District, Shenzhen
  • Shenzhen
  • CN
  • 518102
  • 939301410@qq.com
  • 15625700418

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • 950891051
  • MJCM SARL
  • 78 avenue des Champs Elysees Bureau 326, 75008 Paris, France
  • Paris
  • FR
  • 75008
  • mjcm190928@gmail.com
  • 0033 767213611