Ac 100-240v Digital Led Temperature Controller Thermostat With Air Sensor Tmc-6000

¥5,390
+ 配送料¥699

Ac 100-240v Digital Led Temperature Controller Thermostat With Air Sensor Tmc-6000

  • ブランド: Unbranded

Ac 100-240v Digital Led Temperature Controller Thermostat With Air Sensor Tmc-6000

  • ブランド: Unbranded
価格: ¥5,390
販売元:
¥5,390
+ 配送料¥699

在庫あり

以下の支払い方法を利用することができます

説明

Product function introduction: The one-way temperature controller can set as "refrigerating" or "heating", using 10K general NTC thermistor to control temperature, control the one-way relay (NO, NC) output. The temperature range controlled is -45-110. It is used extensively in various refrigerating and heating situations. Under refrigerating mode, the output opens when the temperature is above (temperature control value + backlash), and stops when temperature is the at temperature control value. Under heating mode, the output opens when the temperature is below (temperature control value - backlash), and stops when temperature is the at temperature control value. The temperature control value and backlash are adjustable. Correction function for temperature deviation is also available. DIN rail-type installation is adopted which is easy and fast for installing. The advanced design of isolating power supply is adopted, which can ensure the controller work steadily, reliably, and continuously when the power supply changes between 100V and 240VADC. Main Features: One-way 10K NTC temperature sensor input One-way NO & NC output Temperature display Shifting between the refrigerating and heating modes Delay protection of compressor Correction of measured temperature deviation Power-down memory protection function Panel introduction 1.The indicator light is lit when the relay NO pulls-in. 2. LED display window: temperature is displayed during work (T temperature = T temperature measured + T deviation) 3. (erected triangle)is parameter plus adjust key under set state; Under work state, press it for long to check the temperature control value set. 4. (SET) set key, press it to start the parameter set state and press one by one to shift to display each parameter. 5. (Inverted triangle)is parameter minus adjust key under set state. 6. If no action is conducted in 3 min after adjusting, the interface will return to the main interface automatically, displaying current temperature. Detailed introduction of the control function: Short name of control function Control function introduction Other introduction Temperature measuring correction Displayed T temperature = T measured temperature + T deviation Temperature control output 1. Under H mode, when T temperatureT temperature control, the relay NO is off, output stops; when T temperature is(T temperature - T backlash), the relay NO pulls-in again, heating output starts; 2. Under L mode, when the T temperatureT temperature control, the relay NO is off, output stops; when T temperature is(T temperature + T backlash), the relay NO pulls-in again, refrigerating output starts; The time for relay output open-- close or close-- open shall not be shorter than the Pt set value. Operation guide: Press(SET)to start setting parameter, press one by one to shift to display each parameter; (erected triangle)(Inverted triangle )is used to adjust the value. After setting, press continuously the(SET) key until the main interface is get. Times pressing(SET) Display Parameter explanation Function introduction and short name Parameter set range Factory setting 1 -H- HL Selection of heating/refrigerating (H is heating mode, L is refrigerating mode) H/L H 2 -1- Parameter 1 3 Upper limit of temperature control Temperature control value when relay NO output stops -45-110 25 4 -2- Parameter 2 5 d Temperature control backlash value 1-30 2 6 -3- Parameter 3 7 Delay time, controlling the minimum delay time of the relay output open-- close or close-- open (the delay time should be set as 2-3 min for refrigerating compressor for protection) 0-300 S 1S 8 -4- Parameter 4 9 SC Correction of measured temperature deviation -25-25 0 Technical Parameter: External dimension (mm):L 93 x W 55 x H 44 Installation mode:The controller installation could be standard DIN rail installation or fixed installation Power supply and consumed power at work:ADC(100-240)V,2W Application environment:-10-50 Display mode:Three LED digit display Key:Press-type membrane key Input:One-way (10K)NTC thermistor temperature sensor output, measuring range of -50-120 Output: 1. One-way relay NO, NC refrigerating/heating output 2. The current capacity of the output contact is 5 ampere of restrictive load and 1 ampere of inductive load. It can control the 1000W electrical heating or electrical motor or water pump of 200W. A.C. contactor is needed to enlarge the capacity for more load. Measurement range:-50-120 Set range: Minimum limit: -45-controlled temperature Maximum limit: controlled temperature-110 Control range:-45-110 Other parameter: 1. The temperature sensing line could be connected with general wire for 100 meters 2. Set the parameter to
  • Fruugo ID: 296740437-663852612
  • EAN: 8154069143948

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Not suitable for children under 36 months old

配送と返品

2日間以内に発送

  • EXPRESS: ¥699 - 間の配達 木 16 10月 2025–木 23 10月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • qianyong
  • High-tech Zone Qianyong Information Consulting Studio
  • 1st Floor,No. 235,Tianshun Road
  • Chengdu
  • CN
  • 610000
  • xushengtech2021@gmail.com
  • 8613689080983

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • VAT SPEED SL
  • VAT SPEED SL
  • Calle Antonio Salvador N99.1
  • Madrid
  • ES
  • 28026
  • services@vatspeed-eu.com
  • 34916321624