Co2 Sensor Module Detector Carbon Dioxide Temperature Humidity 3-in-1 Transmitter 485

¥30,890
配送料無料

Co2 Sensor Module Detector Carbon Dioxide Temperature Humidity 3-in-1 Transmitter 485

  • ブランド: Unbranded

Co2 Sensor Module Detector Carbon Dioxide Temperature Humidity 3-in-1 Transmitter 485

  • ブランド: Unbranded
価格: ¥30,890
販売元:
¥30,890
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

1The new infrared calibration technology is used to measure the CO2 concentration with high accuracy and long service life. 2Support 485 communication, standard Modbus-RTU communication protocol, communication address and baud rate can be set, the farthest communication distance is 2000 meters. 3The shell is made of high quality PVC material, which is durable, wear-resistant and corrosion-resistant. 4Wide measuring range, with temperature compensation function, little affected by temperature. 5Wall mounted installation is adopted, with simple installation method, protection grade of IP65 and high reliability. 6It is widely used in agricultural greenhouse, flower culture, mushroom planting and other occasion requiring CO2 and temperature and humidity monitoring.Condition: 100% Item Type: CO2 Transmitter Material: PVC Power Supply: 10-30V DC Average Current: Line Color Description Power Supply Brown Power Supply (10 - 30V DC) Black Negative Power Communication Yellow 485-A Blue 485-B Basic Communication Parameters: Code 8-Bit Binary Data Bit 8-Bit Parity Bit No Stop Bit 1 Person Error Checking CRC (Redundant Cyclic Code) Baud Rate 2400bit / s, 4800bit / s, 9600 bit / s can be set, the factory default is 4800bit / s Common Problems and Solutions: Possible reasons for the toolnot being able to connect to the PLC or computer: 1. The computer has multiple COM ports. The selected port is incorrect. 2. The address of the toolis wrong, or there are devices with duplicate addresses (factory default is 1). 3. Baud rate, verification mode, data bit, stop bit error. 4. The host polling interval and waiting time are too short, which need to be set above 200ms. 5.485 bus is disconnected, or a and B wires are connected reversely. 6. If the number of equipment is too large or the wiring is too long, the power shall be supplied nearby, 485 intensifier shall be added, and 120 terminal resistance shall be added at the same time. 7. The usb-485 drive is not installed or damaged. 8. The equipment is damaged. 1 x CO2 Sensor1 x Bag of Accessories (2 x Screws, 2 x Screw Cap)1.Please allow 0-1 inch err
  • Fruugo ID: 229689682-490101841
  • EAN: 889613263107

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 火 28 10月 2025–月 03 11月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Fuzhou Oulibogexiangbao Youxiangongsi
  • Fuzhou Oulibogexiangbao Youxiangongsi
  • Gulouqu beihuanxilu108hao yonghengxincun7zuo 2bdanyuan
  • Fuzhou
  • CN
  • 350001
  • ffzzbg@outlook.com
  • 8618359831991

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • EC REP SERVICES SL
  • EC REP SERVICES SL
  • C/GRAN VIA 49, 7 DCH
  • MADRID
  • ES
  • 28013
  • ECREPSERVICE@HOTMAIL.COM
  • 34 910563102