TTL Power Monitoring Communication Module for AC Voltage, Current, Power Frequency with CT (CT Coil 100A)

¥3,249
配送料無料

TTL Power Monitoring Communication Module for AC Voltage, Current, Power Frequency with CT (CT Coil 100A)

  • ブランド: Unbranded

TTL Power Monitoring Communication Module for AC Voltage, Current, Power Frequency with CT (CT Coil 100A)

  • ブランド: Unbranded
希望小売価格: ¥4,199
価格: ¥3,249
得する金額: ¥950 (22%)
販売元:
¥3,249
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

Feature: 1. This AC parameter communication module is mainly used to measure AC voltage, current, active power, frequency, power factor and active energy. 2. The module has no display function and the data is read through the TTL interface. 3. Support for Modbus-RTU standard protocol, including host computer software. 4. Comes with TTL to USB data cable and external CT. 5. The module works for Windows operating systems. Specification: Item Type: Communication Module Measurement Range: AC 80-260V Resolution: 0.1 V Accuracy:0.5% 2. Current: Measurement Range:0-100A Resolution: 0.001 A Accuracy: 0.5% 3. Active Power Measurement Range:0-2.3 KW Min. Measuring Power: 0.4W Resolution: 0.1W 4. Power Factor Measurement Range: 0.00-1.00 Resolution: 0.01 Accuracy:1% 5. Frequency Range:45 Hz-65 Hz Resolution: 0.1 Hz Accuracy: 0.5% 6. Active Electrical Energy Metering Range:0-9999.99 kWh Resolution: 1Wh Accuracy: 0.5% Communication Protocol: 1. Physical layer protocol: Physical layer adopts UART to TTL communication interface Baud rate:9600,8 bit data bit,1 bit stop bit, no check 2. Application layer protocol The application layer supports for Modbus-RTU protocol for communication and currently only supports function codes such as 0x03 (read-hold register), 0x04 (read-input register), 0x06 (write single register), 0x41 (calibration), 0x42 (power zero). The 0x41 function code is limited to internal use (the address can only be 0xF8), used for factory calibration and back-to-factory maintenance, add a password of 16 bits after the function code, the password default is 0x3721. The address range of the slave computer is 0x01 ~ 0xF7, and the address 0x00 is used as the broadcast address. The slave computer does not need to reply to the host, and the address 0xF8 is used as the general address. The address can only be used in a single-slave environment and can be used for calibration and other operations. 3. Read the results of the measurement The command format for the host to read the result of the measurement is (8 bytes in total): Slave computer address + 0x04 + register address high byte + register address low byte + register number high byte + register number low byte + CRC check high byte + CRC check low byte. Reply of slave computer to the following command format is divided into two types: Correct reply: Slave computer address + 0x04 + bytes + registers 1 data high byte + registers 1 data low byte +...+ CRC check high byte + CRC check low byte. Wrong reply: Slave computer address + 0x84 + exception code + CRC check high byte + CRC check low byte. The exception code is read as follows (the same below): 0x01, illegal function; 0x02, illegal address; 0x03, illegal data; 0x04, slave error. The register layout of the measured results is shown in the following table: v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} x\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} Register address Description Resolution 0x000 Voltage value measurement 1LSB corresponds to 0.1V 0x001 Current Measurement Value Low 16 Bits 1LSB corresponds to 0.01A 0x0002 Current Measurement Value High 16 Bits 0x0003 Power Measurement Value Low 16 Bits 1LSB corresponds to 0.1W 0x0004 Power Measurement Value High 16 Bits 0x0005 Energy Measurement Value Low 16 Bits 1LSB corresponds to 1Wh 0x0006 Energy Measurement Value High 16 Bits 0x0007 Frequency Measurement Value 1LSB corresponds to 0.1Hz 0x0008 Power Factor Measurement Value 1LSB corresponds to 0.01 0x0009 Alarm State 0xFFFF alarm,0x0000 no alarm 4. Read and modify the slave parametersIt supports reading and modifying the address and power alarm settings of the slave machine 5. Zero power 6. Calibration 7. CRC check Package List: 1 x Module1 x Data Cable1 x CT1 x User Manual Note: The module TTL interface is a passive interface, it needs external 5V power supply, all 4 ports must be linked at the time of communication, otherwise it can't communicate.
  • Fruugo ID: 413522675-873947086
  • EAN: 7603816554106

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Warning: Please read the product instructions carefully before use to ensure correct use.
シリアルナンバー: 7603816554106

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 火 28 10月 2025–火 04 11月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • No. 1-1, Door 57
  • Shihua Village
  • Qingshan District
  • Wuhan
  • CN
  • 430000
  • goldxinks@163.com
  • 0086 17786498762
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795