説明
1Control Module: When the current is too large or too small, the relay switch will control line to connect and disconnect, or give a signal. 2Detection Range: Can conveniently detect DC 730V current between 010A, and the detection voltage is equal to the input power voltage. 3Practical Using: Comes with error calibration function, and the display can also be turned off for a long time to reduce power consumption. 4High Accuracy: The current detection module has a high accuracy up to 0.01A, which ensures small error for easier and more efficient work. 5Easy Operation: Digital display enables a clear view to the work status, and the simple operation will help to prevent the stalling as well.
Item Type: DC Current Detection ModuleProduct Model: YYI-2. When the detection current is too large or too small, the control relay switch will control the circuit to be on or off, or give a signal; Detection Range: DC 7-30v current between 0-10A, the detection voltage is equal to the input power voltage; Detection Accuracy: 0.01A (10mA)Error Calibration: With error calibration function, and the display can be turned off for a long time to reduce power consumption; Standby Current: About 20mA; Relay Output: Can control the on and off of DC lines within 10A; Function Description: 1. P-11: When the measured current is greater than I1, the relay is closed; when the measured current is less than I1 again, the relay is disconnected; 2. P-12: When the measured current is greater than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; 3. P-21: When the measured current is greater than I2, the relay is closed; when the measured current is less than I1, the relay is disconnected; 4. P-22: When the measured current is greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; 5. P-31: When the measured current is less than I1, the relay is closed; when the current is greater than I2, the relay is disconnected; 6. P-32: When the measured current is less than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; 7. P-41: When the measured current is between I1 and I2, the relay is closed, otherwise the relay is disconnected;8. P-42: When the measured current is between I1 and I2, the relay is closed; and it will always stay closed until the circuit board is powered off; 9. P-51: When the measured current is less than I1 or greater than I2, the relay is closed, otherwise the relay is disconnected; 10. P-52: When the measured current is less than I1 or greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; Setting Instructions:1. Power on to display the measured current; (if the measured current terminal is suspended, the number of digital display is normal); 2. The first time K1 is pressed, it takes more than 1 second to be effective to prevent false triggering. The screen displays: P 11: K2 adjustment mode, K3 adjustment function; 3. Press K1 for the second time, the screen flashes: 0.05 means that the value of the threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus; 4. Press K1 for the third time, the screen flashes: 0.10 means the value of the threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus; 5. Press K1 for the fourth time, the screen displays the measured current; it means it enters the standby state;6. In standby mode, long press K2 or K3 to fine tune the measured current error.
1 x DC Current Detection Module
-
ブランド:
Unbranded
-
カテゴリー:
林業・伐採
-
Fruugo ID:
212810995-453729954
-
EAN:
5328792850630
製品安全情報
以下に概説するこの製品に固有の製品安全性情報を参照してください。
以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。
製品安全ラベル
安全上の警告:
Carefully reading the instruction manual is the first step towards safe use.