DC 12V/AC110V/220V LED Digital Timer Control Relay Switch Timer Delay Switch Trigger Delay Switch Board For Water Pump

¥3,649
配送料無料

DC 12V/AC110V/220V LED Digital Timer Control Relay Switch Timer Delay Switch Trigger Delay Switch Board For Water Pump

  • ブランド: Unbranded

DC 12V/AC110V/220V LED Digital Timer Control Relay Switch Timer Delay Switch Trigger Delay Switch Board For Water Pump

  • ブランド: Unbranded
価格: ¥3,649
販売元:
¥3,649
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

["DC12V AC220V/85-265V Digital Display for Time Relay Module Timer Cycle Control Relay Module\r\nbrand new and high quality\r\n\r\nFeatures:\r\nTiming range: 0-999ms, 0-999s, 0-999m, 0-999h \r\nPower supply voltage: DC12V, AC85-265V (110V 220V)\r\nStatic power: <0.6W\r\nPower: <2000W(maximum) \r\nWorking current: 10A(maximum) \r\nDimensions: 71x39x25mm/2.8x1.54x0.98inch\r\nColor: Black\r\nQuantity: 1 Pc\r\nNote: 1.for DC and AC wiring are the same, the positive pole corresponds to the live line, and the negative pole corresponds to the neutral line.\r\n 2.Please allow 0-1cm error due to manual measurement. pls make sure you do not mind before you bid.\r\n 3.Due to the difference between different monitors, the picture may not reflect the actual color of the item. Thank you!\r\n\r\nPackage includes:\r\n1 x for Time Delay Relay Module\r\n\r\n\r\n\r\n---------------------------------\r\nProduct use instructions:\r\nThis product has four function keys: increase button, decrease button, set button, confirm button\r\nAfter the user gets the product, first understand the function buttons of the product, which is beneficial to the customer's next use.\r\n\r\nfor Time setting: Short press the setting button, the T1 digital tube will flash. During the flashing period, the timing for time T1 is set by adding or subtracting the button. After setting, press the setting button again, the T2 digital tube will flash, and the button will be added or subtracted during the flashing. Set the timing for time T2. There are two ways to save data after setting. The first can wait for 6s, the digital tube stops flashing, the system automatically saves the setting for time, and the second can press the setting button again to save the data.\r\n\r\nParameter setting: Press and hold the setting button to enter the parameter setting mode. There are three sets of parameters for the user to set P0, P1, P2.\r\nP0: Timed range, P1: Operating mode, P2: Display brightness adjustment. P0, P1, P2 can be switched by short pressing the setting button. Under the corresponding parameters, the corresponding parameters can be set by adding or subtracting by pressing the button.\r\nP0--0 represents a timing range of 0.1 seconds.\r\nP0--1 represents the timing range is seconds.\r\nP0--2 represents the timing range is a fraction.\r\nP0--3 represents the timing range is for time.\r\nP1--0: Relay delay after T1 for time (T1 timing).\r\nP1--1: The relay is released after the delay of T1 for time (T1 timing).\r\nP1--2: After the delay for time T1, the relay is closed (T1 timing), and then the relay is released after T2 for time (T2 timing), and ends.\r\nP1--3: The relay is released after the delay for time T1 (T1 timing), and then the relay is closed after the T2 for time (T2 timing), and ends.\r\nP1--4: After the delay for time T1, the relay is closed (T1 timing), and then the relay is released after T2 for time (T2 timing), and the cycle is repeated.\r\nP1--5: The relay is released after the delay for time T1 (T1 timing), and then the relay is closed after the T2 for time (T2 timing), and the cycle is repeated.\r\nP2--0 to P2--5 are display brightness adjustments that the user can set based on comfort.\r\nP2--OFF: Low power mode, the user sets P2 to OFF mode, the system will automatically turn off the display after 10s, enter the low power mode, press any button to wake up.\r\n\r\nThe confirmation button has two major functions:\r\nFunction 1: After all the parameter settings are completed, press the Enter for key to save the setting data and start working. Pressing the ENTER button again during operation will implement the pause function, the relay will be disconnected, and the button will be restored again.\r\nFunction 2: Trigger function again. After the timer finishes working normally, it needs to work again. Short press the confirmation button to re-time.\r\n\r\nFor example: For example, a customer needs to turn on the machine for 10 seconds, shut down for 20 seconds, and cycle. The setting method is as follows:\r\n T1 sets for time 10, T2 sets for time 20\r\nP0-1 (T1 timing range is seconds)\r\n P1—5 (the timer working mode is to stop and cycle all the for time after working)"]
  • Fruugo ID: 351700398-766299113
  • EAN: 7900000589792

配送と返品

24時間以内に発送

  • STANDARD: 無料 - 間の配達 金 10 10月 2025–月 13 10月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Shenzhen Jianming Technology Co., Ltd.
  • Shenzhen Jianming Technology Co., Ltd.
  • 611, 6th Floor, Longsheng Commercial Building, Dalang Street
  • Shenzhen
  • China
  • 518000
  • ytirne7dwq@163.com
  • 18818900735

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • Yating He
  • E-CrossStu GmbH
  • 69 Mainzer Landstrasse
  • Frankfurt am Main
  • Germany
  • 60329
  • E-crossstu@web.de
  • +4969332967674