DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

¥1,449
配送料無料

DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

  • ブランド: Unbranded

DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

  • ブランド: Unbranded
希望小売価格: ¥1,899
価格: ¥1,449
得する金額: ¥450 (23%)
販売元:
¥1,449
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

Features:To achieve fast high frequency turn-on andoff circuit, an unlimited number of switching times.No noise was made during turning on/off, nospark, and no electromagnetic interference.Compared to normal electromagnetic relaymodules, it has a longer service life.Dual-MOS in parallel active output, lower innerresistance, larger current, strong power; at room temperature, operatingcurrent is up to 15A, power up to 400W, that can be used for most equipment.Wide voltage input from 5V to 36V, normallyused for controlling DC motors, lights, LED strips, micro-pumps, solenoidvalves, etc., very convenient.It has an emergency stop function ("STOP" button)and reverse input protection.Automatically enter sleep mode and shut offdisplay if no operation in 5 minutes, and will be wake up by pressing anybutton.You can set different OP, CL, LOPparameters, which are independent of each other, and are saved separately;All parameter settings will be savedautomatically if there is a power failure. Specifications:Voltage: DC 5V~36V.Trigger Signal Source: High voltage leveltrigger (3.0V~24V), signal ground and system ground are not on common ground toimprove the system's anti-jamming capability (you can also connect them oncommon ground).Output Capacity: DC 5V~36V, at roomtemperature, continuous current is 15A, power 400W. With enhanced heatdissipation, the current can be up to 30A.Quiescent Current: 20mAOperating Current:50mAWorking Temperature: -40~85Clocking (Time Delay) Range: 0.1seconds to999minutesSize: 60*34*12mm / 2.36*1.33*0.47"Instruction: Operating Mode:P1: trigger signal, the relay is on"OP" time, and then disconnect; in the "OP" time, asfollows:P1.1: signal is triggered again, invalidP1.2: signal is triggered again, the clockingis resetP1.3: Signal is trigger again reset, relayoff, and stop the clocking;P-2: trigger signal, the relay off"CL" of time, the relay on "OP" time, and then disconnectrelay after clocking;P3.1: trigger signal, the relay is turnedon after the "OP" time, the relay off "CL" time, then theoperation cycles; if trigger signal again during the cycle, the relay off, stopclocking; the number of cycles times ( "LOP ") can be set.P3.2: without triggering signal after poweron, the relay is on "OP" time, the relay off "CL" time, thenthe operation cycles; the number of cycles times ( "LOP ") can beset.P-4: signal holding function. If there is triggersignal, clocking is reset, the relay remains on; when the signal disappears,after clocking "OP" time, the relay is off; if another signal istriggered during clocking, clocking will be reset.How to Set Clocking Range:After setting the parameter value at modeselection, press "STOP" button to set the clocking range;XXX. The last decimal point lights up,range: 1 second to 999 seconds.XX. X The second last decimal point lightsup, range: 0.1 seconds to 99.9 secondsX. X. X. all 3 decimal points light up,range: 1 minute to 999 minutes.For example, if you want to set"OP" as 3.2 seconds, light up the second last decimal point, and setdigit display as 03.2Parameter Description: "OP" - ontime, "CL" - off time, "LOP" - number of cycle times (1-999times, "---" represents infinite loop).These parameters are independent of each other,but are shared by each mode. For example, in P1.1 mode, set the on-time"OP" is 5 seconds, if you switch to P1.2 mode, its "OP"will also be 5 seconds.In the main interface (display 000), press"SET" button will display "OP" ( "CL","LOP") and the corresponding time XXX;If the mode (such as the mode P1.1, P1.2,P1.3) only has "OP" time, press the "SET" key to displayonly the "OP" and the corresponding time;Some models (such as the mode P3.1, P3.2)have parameters "OP", "CL", "LOP", press"SET" button will display "OP" and the corresponding time, "CL" and the corresponding time, "LOP" and the corresponding number of times;After setting mode, in the main interface press"SET" key to see information about the parameters of the currentmode, very convenient.How to Set Parameters:1. First, read the instructions todetermine the required operating mode.2. The module is powered up, the display atthe current work mode (P1.1 default mode), then enter the main interface; pressand hold "SET" button for 2 seconds to enter mode selectioninterface; then press "UP", "DOWN" button to select themode (P1.1 ~ P-4).3. Select the mode (such as P3.2), thenpress the "SET" button, the parameter to be set flashes ("OP" on-time, "CL" off time, "LOP" cycles ("---" represents infinite loop)), press(or press and hold)"UP", "DOWN" button to adjust the parameter value; thenpress the "STOP" key to set the decimal point position to select the clockingrange (0.1 seconds to 999 minutes); press the "SET" button to set thenext parameters of the current mode, method is same as above.4. After the parameters are set, press andhold "SET" button for 2 seconds, then the current mode will flashonce, and then return to the main interface, which means the parameters are successfullyset.The main inte
  • Fruugo ID: 419699423-884528988
  • EAN: 7890797634143

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Warning: Please read the product instructions carefully before use to ensure correct use.
シリアルナンバー: 7890797634143

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 水 22 10月 2025–水 29 10月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Shenzhen Gujun Technology Co., Ltd.
  • Shenzhen Gujun Technology Co., Ltd.
  • 1303, 13/F, Tower B, TCL Building, No. 6 Gaoxin Nandao Road, Yuehai Street
  • Nanshan District
  • Shenzhen
  • Guangdong
  • CN
  • 518067
  • idyaiy16984@163.com
  • 13038870349
  • https://hengruigongju.1688.com/page/index.html?spm=0.0.wp_pc_common_header_companyName_undefined.0

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795
  • https://www.ozon.ru/seller/topstore-600244/products/?miniapp=seller_600244&__rr=1&abt_att=1