説明
1. What is the PO versions? PO is self-locking mode. For example, when the external forward switch (K1) is pressed, the motor will immediately rotate forward. At this time, the switch will be released immediately, and the motor will still keep rotating forward. It will not stop until it encounters the reverse rotation signal (K2) or the forward rotation stop signal (SW1).
2. What are the requirements for the signal, can the sensor be connected? The signal is active low, it can be a three-wire sensor (NPN-NO type), K1 K2 Sw1 SW2 is still this specification.
3. What is the limit signal? The limit signal can also be called a stop signal. The limit signal is trigger type and level-enabled. For example, if a short limit signal is encountered during forward rotation, it will stop, even if the limit signal disappears, it will still stop. The forward rotation signal must be restarted to run forward again.
4. What is the input and output voltage? The input voltage range of TKS-M8 is 4v-40v, but to reliable operation, it is recommended to use it in the range of 6V-36V. The output motor is the same as the input voltage.
Working voltage:wide voltage DC4V-40V
Module power consumption:0.6W (without load motor), static 0.1W
Signal input:active low level, the input is the negative pole of the optocoupler. When the voltage is lower than 2V, it is considered that there is a signal
Response speed:K1 K2 is 20mS, SW1 SW2 is 50mS
Output current:20A
Action life: 150,000 times
PO/Standard version:After a short trigger, the motor will keep running until it encounters a limit or commutation signal
Colour:Green
Material:PCB
Size:83x46x20mm
Package Contents:
1 * P0 Forward/reverse controller
Only the above package content, other products are not included.
Note: Light reflection and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.
4. What is the input and output voltage? The input voltage range of TKS-M8 is 4v-40v, but to reliable operation, it is recommended to use it in the range of 6V-36V. The output motor is the same as the input voltage.
3. What is the limit signal? The limit signal can also be called a stop signal. The limit signal is trigger type and level-enabled. For example, if a short limit signal is encountered during forward rotation, it will stop, even if the limit signal disappears, it will still stop. The forward rotation signal must be restarted to run forward again.
2. What are the requirements for the signal, can the sensor be connected? The signal is active low, it can be a three-wire sensor (NPN-NO type), K1 K2 Sw1 SW2 is still this specification.
1. What is the PO versions? PO is self-locking mode. For example, when the external forward switch (K1) is pressed, the motor will immediately rotate forward. At this time, the switch will be released immediately, and the motor will still keep rotating forward. It will not stop until it encounters the reverse rotation signal (K2) or the forward rotation stop signal (SW1).
-
Fruugo ID:
425493417-893855879
-
EAN:
9121763188871
製品安全情報
以下に概説するこの製品に固有の製品安全性情報を参照してください。
以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。
安全上の警告:
WARNING: Proper Installation. If you do not have the necessary equipment or expertise, or are unsure whether the mounting surface is adequate to support the device, consult a professional installer.
材料:
Other