DC 6V-30V DDC-431 Timer Delay Relay Switch Digital DC 12V Data Save Delay Controller

¥2,699
配送料無料

DC 6V-30V DDC-431 Timer Delay Relay Switch Digital DC 12V Data Save Delay Controller

  • ブランド: Unbranded

DC 6V-30V DDC-431 Timer Delay Relay Switch Digital DC 12V Data Save Delay Controller

  • ブランド: Unbranded
希望小売価格: ¥2,999
価格: ¥2,699
得する金額: ¥300 (10%)
販売元:
¥2,699
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

DC 12V DDC-431 Timer Delay Relay Switch Digital Data Save Delay Controller DC 6V-30V Description: - Powerful function, one-button emergency stop function (STOP button), with reverse connection protection, reverse connection without burning, power-off memory. - Increased sleep mode, after enabling, No operation within 5 minutes, automatically turn off the display, wake up any button! - You can set different OP, CL, LOP parameters, these parameters are independent of each other, save the setting parameters automatically power-down save and other functions, almost meet all needs! Product manual: Working voltage: DC6V-DC30V (wide voltage anti-connection protection) Trigger signal source: high-level trigger DC 3.0V24V signal ground and system ground to improve the system's anti-interference ability can also short-circuit the ground Output capacity: controllable DC 30V/10A or AC 250V/10A equipment Product size: 64mm*35mm*19.3mm Mounting hole: diameter 3mm Working temperature: -40 C ~ 85 C Operating mode: P1 mode: After the signal is triggered, the relay turns on the OP time, then turns off; in the OP time, the following operation P1.1: The signal is triggered again. P1.2: Signal triggers re-timed again P1.3: The signal triggers reset again, the relay is disconnected, and the timing is stopped. P-2: Give the trigger signal, after the relay turns off the CL time, the relay turns on the OP time. After the timing is completed, the relay is turned off. P3.1: Give the trigger signal, after the relay turns on the OP time, the relay turns off the CL time, then loops the above action, the signal is given again in the cycle, the relay is disconnected, the timing is stopped; the number of cycles (LOP) can be set P3.2: No trigger signal is required after power-on, the relay turns on OP time, the relay turns off CL time, and the above actions are cycled; the number of cycles (LOP) can be set P-4: Signal hold function If there is a trigger signal, the timing is cleared, the relay remains on; when the signal disappears, the relay is turned off after timing the OP; during the timing, there is a signal, and the timing is cleared. Relay enable mode: ON : The relay is allowed to conduct during the OP conduction time. OFF : The relay is prohibited from being turned on and is always off. Short press the STOP button on the main interface to switch between ON and OFF. The current state will flash, then return to the main interface. This function is the emergency stop function, one button to open and close the relay. Sleep mode (long press the stop button to view the current mode): C-P sleep mode: within five minutes, without any operation, the digital tube automatically turns off the display, the program runs normally. O-d normal mode: the digital tube is always on display Press and hold the STOP button for 2 seconds and then release to switch the C-P and O-d states. The current state will flash and then return to the main interface. Timing range: How to choose the timing range After setting the parameter value in the mode selection interface, press the STOP button to select the timing range. XXX. Decimal point is in one place, timing range: 1 second to 999 seconds XX.X decimal point in ten, timing range: 0.1 seconds to 99.9 seconds X.X.X. The decimal point is fully illuminated, the timing range is from 1 minute to 999 minutes. For example, if you want to set the OP to 3.2 seconds, move the decimal point to ten digits, and the digital tube displays 03.2. Parameter description: OP on time, CL off time, LOP cycle number 1-999 times, "---" stands for infinite loop These parameters are independent of each other, but each mode shares these parameters. For example, when the on-time OP is set to 5 seconds in P1.1, the user wants to switch to the P1.2 mode, then when entering the P1.2 setting corresponding parameters, the OP also Will be 5 seconds Displaying 000 on the main interface and pressing the SET button will display OPL, LOP and corresponding time XXX If only OP in the mode, such as mode P1.1, P1.2, P1.3 time, then short press SET button will only display OP and corresponding time If the mode has OP, CL, LOP such as mode P3.1, P3.2 short press SET button will display OP and corresponding time, CL and corresponding time, LOP and corresponding times After setting the mode, it is very convenient to view the parameters set in the current mode by pressing the SET button on the main interface. How to set parameters: 1) First determine the working mode of the relay According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default P1.1 mode), then enter the main interface "press and hold the SET button for 2 seconds and then release" to enter the mode selection. Interface, select the mode to be set
  • Fruugo ID: 100247484-210813223
  • EAN: 8456000426548

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark

配送と返品

24時間以内に発送

  • EXPRESS: 無料 - 間の配達 金 10 10月 2025–火 14 10月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • ShenZhenShiFuJingKeJiYouXianGongSi
  • ShenZhenShiFuJingKeJiYouXianGongSi
  • GuangMingXinQuGongMingJieDaoYuLvCunErQu206Hao911Fang
  • Shenzhen
  • China
  • 518106
  • uiyhfsd34h@hotmail.com
  • 19168536521

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • CrossStYAting
  • E-CrossStu GmbH
  • 69 Mainzer Landstrasse
  • Frankfurt am Main
  • Germany
  • 60329
  • E-crossstu@web.de
  • +4969332967674