DC 6V~30V Trigger Delay On/Off Cycle Timer Relay Switch Module w/Digit LED Display Micro USB 5V

¥1,299
+ 配送料¥1,949

DC 6V~30V Trigger Delay On/Off Cycle Timer Relay Switch Module w/Digit LED Display Micro USB 5V

  • ブランド: Unbranded

DC 6V~30V Trigger Delay On/Off Cycle Timer Relay Switch Module w/Digit LED Display Micro USB 5V

  • ブランド: Unbranded
価格: ¥1,299
販売元:
¥1,299
+ 配送料¥1,949

在庫あり

以下の支払い方法を利用することができます

説明

Features:Wide DC power supply voltage from 6V to 30V, support micro USB 5.0V power supply, very convenient to use.Interface is clear, simple and powerful, easy to understand, almost meet all your needs.The module supports reverse input protection, and there is a STOP button for emergency stop function. Added sleep mode, it will automatically turn off display if no operation in 5 minutes after enabled, and you can press any button to wake it up.You can set different OP, CL, LOP parameters, these parameters were independent of each other and saved respectively.All set parameters will be automatically saved if there is a power failure.With optical coupling isolation, improved anti-interference ability, industrial level circuit board.Specifications:Voltage: 6V~30V(support micro USB 5.0V)Quiescent Current: 20mAOperating Current: 50mAOperating Temperature: -40~85Size: Approx. 6.2*3.8*1.7cm / 2.44*1.49*0.67"Timing Range: 0.1seconds to 999 minutes(continuously adjustable)Instruction:Operation Mode:P1: After triggering signal, switch isconnected for "OP"time, then disconnected; within the "OP"time:P1.1:if trigger signal again,it isinvalid.P1.2: if trigger signal again, restart timing.P1.3: if trigger signal again, switch is disconnected, stop timing.P-2: After triggeringsignal, switch is disconnected for "CL"time, then switch is connected for "OP"time, and disconnect after timing.P3.1: After triggering signal, switch is connectedfor "OP"time, then switch is disconnected for "CL"time, and enter loop. Iftrigger signal during loop, switch is disconnected and stop timing. The loop times(LOP) can be set.P3.2: After power on, no need triggersignal, switch will be connected for "OP"time, then disconnected for "CL"time, and enter loop. The loop times (LOP) can be setP-4: Signal holding function. If there is triggersignal, timing will be reset, switch remains connected; when the signaldisappears, it will disconnect after "OP"time. During timing, if there is asignal, timing will be reset.OP: Connect time. CL: Disconnect time. LOP:Loop times(1~999, "---"indicates infinite times)All above parameters are independent fromeach other, but all modes use the same parameters. For example, if set OP timeas 5 seconds in P1.1, then change to P1.2, then the OP time in P1.2 will also be5 seconds.Press SET button at the main interface (display000), it will show OP(CL, LOP) and corresponding time.If there is only OP mode (e.g. P1.1,P1.2, P1.3), press SET button todisplay OP and corresponding time only.If there are OP, CL, LOP modes (e.g.P3.1,P3.2), press SET button to display OP, CL, LOP and corresponding time.After setting mode, press SET button at themain interface to check the parameter of present mode.How to Choose Timing Range:After setting parameter in the interface selectionmode, press the STOP button to select the time range:XXX. If the last decimalpoint lights up, the time range is 1sec to 999sec.XX.X If the second lastdecimal point lights up, the time range is 0.1sec to 99.9sec.X.X.X.If all decimal pointslight up, the time range is is 1 min to 999 min.For example, if you set OP as 3.2 seconds,the make the second last point light up, and it displays 03.2How to Set Parameter:1. Make sure operation mode.2. According to the operation mode, at maininterface(after power on, it will flash present mode then enter main interface),press and hold SET button for 2 seconds to enter mode selection interface, thenpress UP, DOWN button to choose mode (P1.1~P-4) 3. After selecting mode, press short SET buttonto set the corresponding parameter, then the parameter you want to set willflash. Press UP, DOWN button to set value, then press STOP button to selecttime range. Press SET button to set next parameter.4. After setting mode parameter, press andhold the SET button for 2 seconds then the present mode will flash, and go backto the main interface.Main interface: when relay does not work,it shows "000" (no decimal point); when relay is working, it shows decimalpointMode Selection Interface: Press and hold SETbutton to enter. After setting, press and hold SET button to back to maininterface.Relay Enable Mode:1. NO: Connection is allowed during OP time.2. OFF: Connection is not allowed, always turnedoff.Press STOP button at main interface tochange between ON and OFF, the present state will flash then back to maininterface. (This is emergency stop function, used to disconnect relay.)Sleep Mode:C-P sleep mode: if no operation within 5minutes; display will close automatically while procedure runs normally.O-d normal mode: displays always shows.Press and hold STOP button for 2 seconds tochange between C-P and O-d, present state will flash and then back to the maininterface.Package Includes:1 x Timer Switch ModuleNote:Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering. .
  • Fruugo ID: 367907010-796631493

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Warning: Please read the product instructions carefully before use to ensure correct use.

配送と返品

3日間以内に発送

  • STANDARD: ¥1,949 - 間の配達 火 14 10月 2025–水 22 10月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Guangzhou Shanli Trading Co., Ltd.
  • Pomeranian Official Store 4
  • Room 409-2, Building 3, No. 6, Hanqi Avenue, Dalong Street, Panyu District, Guangzhou
  • Guangzhou
  • China
  • 511400
  • wangshisan1313@126.com
  • 13246484773

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • DISCOUNT INDUSTRY
  • DISCOUNT INDUSTRY
  • 10 Rue Des Grands Pres, 60230 Chambly, Oise, France
  • Chambly
  • France
  • 60230
  • DISCOUNT-INDUSTRY@outlook.com
  • 0033 748562127