DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid Switch 220V Relay Switch JH2

¥2,449
+ 配送料¥1,099

DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid Switch 220V Relay Switch JH2

販売元:

¥2,449

保存する ¥1,800 (42%)

希望小売価格

¥4,249
在庫あり
+ 配送料¥1,099

14日間返品ポリシー

支払い方法:

  • ブランド: Unbranded

商品詳細

商品詳細

DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid Switch 220V Relay Switch JH2

Single-control UP pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B(blue)-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common line.D(green) and E(yellow)are connected with C (black). Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common line.A and B-disconnected Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected Joint control UP and DOWN pool installation instructions :A-Upper water level control point in UP pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto. C-Should be placed in bottom of UP and DOWN pools as the common line.D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected Type:DF-96D Updated version Working voltage : AC 220V/50HZ Max Current :10A(Use the 30A Delay) Installation:Din Rail Mount Power consumption less than equal 2W transmission
  • Fruugo ID: 490921225-1014178162
  • EAN: 5695008359684
安全性

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • jinghang-2
  • Hengyang Lengfei Trading Co., Ltd
  • Room 1068, No. 52, Yancheng Road, Yueping Community, Tianmashan Street
  • Hengyang
  • CN
  • 421001
  • [email protected]
  • 13768621315

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • EU Consulten Srls
  • EU Consulten Srls
  • Via Varessina 55 Milano 20156 Italia
  • Milano
  • IT
  • 20156
  • [email protected]
  • 39 3285832654
配送

配達

2日間以内に発送

  • STANDARD: ¥1,099 - 間の配達 月 23 11月 2026–月 30 11月 2026

中国より発送。

返品

返品

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。

全額返金ポリシーを見る