Duoyi Dyxz-02 Voltage Indicator Tester/ Non-contact Phase Sequence Detector Indicator Detector Meter Led Display 3 Phase Tester

¥9,690
+ 配送料¥1,899

Duoyi Dyxz-02 Voltage Indicator Tester/ Non-contact Phase Sequence Detector Indicator Detector Meter Led Display 3 Phase Tester

  • ブランド: Unbranded

Duoyi Dyxz-02 Voltage Indicator Tester/ Non-contact Phase Sequence Detector Indicator Detector Meter Led Display 3 Phase Tester

  • ブランド: Unbranded
希望小売価格: ¥12,890
価格: ¥9,690
得する金額: ¥3,200 (24%)
販売元:
¥9,690
+ 配送料¥1,899

在庫あり

以下の支払い方法を利用することができます

説明

DYXZ-02 Voltage Indicator Tester Non-Contact Phase Sequence Detector Indicator Detector Meter LED Display 3 Phase Tester Dear friends, this series updated with a new model "DYXZ-01", which has a new function than DYXZ-02 - "Detect the motor rotation with non-contact magnet detection method". To learn more about the specifications of DYXZ-01, Please click this text to jump. Links to new products will be more discounted Product Feature 1.DYXZ-02 non-contact phase rotation tester designs for quick , easy and accurate detection of three phase sequence in motor installation and repair . The non-connection to insulated conductor avoids uncertain and difficult connections to bare high voltage wires 2.This is a phase detector, designed to perform phase sequence checks and live line checks of a 3-phase circuit using a static induction voltage clip. 3.The static induction voltage clips are used to be able to clip on a cladded wire.It is small with a CAT 600V safety rating. Red LED lamps are used to make the indication visible in dimly lit areas.The direction of phase sequence can be checked easily using the LED lamps, which blink in order. Packing list Phase Detector: *1 Acceory bag:*1 Certificate of conformity *1 English manual*1 Specifications Click the picture to buy DYXZ-01 Advantage: Non-contact rotating magnetic field Indication (Motor Rotation detection) 1). Basic Specifications Function Phase detection (positive/negative) Voltage detection method Static induction Object to be connected Insulated wire (nominal sectional area of the conductor: 2 to 120mm2, finished outer diameter: up to 17mm) Performance-guarantee voltage range 3-phase, 70V to 600 VAC (sine wave,continuous) Operating frequency range 45Hz to 66Hz 2). Display Phase-detection indication Positive phase sequence: The four phase-sequence lamps blink order (clockwise) and the buzzer sounds intermittently. Negative phase sequence: The four phase-sequence lamps blink in order (counterclockwise) and the buzzer sounds continuously. Line-voltage indication R-S lamp, S-T lamp Power indication Power ON lamp: lights up (Power ON) blinks (Battery Low) 3). General Specifications Operating temperature and humidity -10 to 40(32 to 104), 80%RH or le ( with no condensation) Storage temperature and humidity -20 to 60 (-4 to 140), 80%RH or le (with no condensation) Location for use Altitude up to 2000m(6562 feet), indoor Maximum rated voltage to earth 600V Dielectric strength 5.4kVrm Power supply Rated supply voltage 1.5VDC2 Two AA size batterie Maximum rated power 300mVA Continuous operating time* Approx.70 hours(Power ON, Standby state, using R6P manganese battery) *Battery life Auto Power Off (This function can not Be canceled.) The power will be turned off automatically if the Instrument remains idle for 15 minutes after the power is turned on. To reset, turn the power on again using the Power ON switch. Cable length Approx. 0.7m Dimensions and ma Approx. 70W75H30Dmm(2.76W2.95H1.18D) (excluding projections), Approx. 200g(7.1oz) Applicable standard Safety EN61010-1:2001,EN61010-031:2002 Pollution degree2, Measurement category CAT III(600V)(anticipated transient overvoltage 6000V) EMC EN61326:1997+A1:1998+A2:2001 Test operation 1. Phase Detection CAUTION ! HIGH VOLTAGE ! (1)Connection: Connect the three non-contact alligator clips to the three phase power cables. (2)The symbol or each clip should be placed at the center of each cables. (3)Pre ON,lightA,B,C flashes once to power on the tester. (4)In case the A,B,C are lit up , R is on if positive CW is detected. If in negative CCW, L is on. If one or more of light A,B,C does not light up , it means the relevant phase is open. In this case, R or L does not represent the indication. (5)Pre OFF to shut down the tester after use 2.Live Voltage Detection CAUTION ! HIGH VOLTAGE ! (1)Connect any of the alligator clips to the conductor. If the conductor is powered on (Voltage within 70~600V AC),the relevant light A,B,C should light up.This can quickly determine if the conductor is powered on. (2)Clips and lights reference table Clips Lights A (yellow ,left) Light A B(green ,middle) Light B C(red , right) Light C Packing list Phase Detector: *1 Acceory bag:*1 Certificate of conformity *1 English manual*1
  • ブランド: Unbranded
  • カテゴリー: 水分計
  • サイズ: DYXZ-01
  • Fruugo ID: 234725807-502037718
  • EAN: 9795179365463

配送と返品

24時間以内に発送

  • STANDARD: ¥1,899 - 間の配達 木 16 10月 2025–金 24 10月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る