FV-500Hz10V Frequency Voltage Converter Module 0~500hz to 0~10V Digital to Analog Signal Module

¥2,849
配送料無料

FV-500Hz10V Frequency Voltage Converter Module 0~500hz to 0~10V Digital to Analog Signal Module

  • ブランド: Unbranded

FV-500Hz10V Frequency Voltage Converter Module 0~500hz to 0~10V Digital to Analog Signal Module

  • ブランド: Unbranded
希望小売価格: ¥4,749
価格: ¥2,849
得する金額: ¥1,900 (40%)
販売元:
¥2,849
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

Features 1、The module can be used for interface conversion between PLC and frequency converter or matching control of interface between motion control card and frequency converter. 2、The converter module is to convert 0~500hz digital signal into 0~10V analog signal. 3、Input pulse level of 5/12/24V can be directly input without resistance.But input signal frequency should maintain more than 0.5 seconds. 4、All parts of the converter module are well-selected of good durability and high quality. 5、The module is stable and has great performance while using. Specification Features: The converter module is to convert 0~500hz digital signal into 0~10V analog signal. The module can be used for interface conversion between PLC and frequency converter or matching control of interface between motion control card and frequency converter. Input pulse level of 5/12/24V can be directly input without resistance.But input signal frequency should maintain more than 0.5 seconds. All parts of the converter module are well-selected of good durability and high quality. The module is stable and has great performance while using. Specification: Size:4.5 x 4.7 x 1.7cm / 1.77 x 1.85 x 0.67in Relationship,Linearity: 50Hz to 1V 250hz to 5V 500hz to 10V Package List: 1 x Converter Module Note: At 24 levels, the power supply needs to be powered by 24VDC 3. The signal input end is isolated by diaphragm. Guaranteed anti-interference ability. 4. If you need to use PLC, support NPN type. Must have a ground wire. 5, if you need to use the encoder, the encoder is required to continue to rotate at a constant speed for more than 0.5 seconds. 7. If the signal input is turbine flow, etc., due to signal matching, an 817 diaphragm and a resistor must be added to match the flowmeter to normal function. 8. Correspondence in use If there is a deviation, you can adjust the blue potentiometer on the board to calibrate. At the time of shipment, we have adjusted the F/v potentiometer to a certain correspondence. It is generally not recommended to adjust it by itself. Package List
  • Fruugo ID: 271639420-602151889
  • EAN: 9308869116520

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 木 16 10月 2025–水 22 10月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る