Lab Biological Trinocular Microscope 38.5x17.5x13cm 360° Rotate

¥51,690
+ 配送料¥2,549

Lab Biological Trinocular Microscope 38.5x17.5x13cm 360° Rotate

  • ブランド: Unbranded

Lab Biological Trinocular Microscope 38.5x17.5x13cm 360° Rotate

  • ブランド: Unbranded
希望小売価格: ¥79,590
価格: ¥51,690
得する金額: ¥27,900 (35%)
販売元:
¥51,690
+ 配送料¥2,549

在庫あり

以下の支払い方法を利用することができます

説明

Lab Biological Trinocular Microscope 360 Degree Rotation Temperature Adjustable Video Microscope Item Type: Biological Trinocular Microscope Material: Iron Product Size: Microscope Size: Approx. 38.5x17.5x13cm / 15.2x6.9x5.1in Storage Case Size: Approx. 46x28x18cm / 18.1x11.0x7.1in Gross Weight: 5300g/11.7lb Use: Mites, Sperm, Aquaculture Common problems and solutions: I. Lamp light source brightness is not enough: 1. The dimming twist to the maximum. 2. Spotlight mirror at the light bar operating lever to the leftmost. 3. To confirm whether the spotlight mirror position is too low, such as is adjusted upward, the height of the non contact angle carrier shall prevail. 4. Confirm whether the spotting scope in the center of the field of view, screw carefully adjusted. II. Image can not be displayed through the screen: 1. Check whether the screen switch is open. 2. Check the lens barrel light transmission push-pull rod has not pushed and pulled the correct. III. Switch open when the light bulb does not light: 1. Check whether the power is on. IV. Bulb flicker or brightness is not enough: 3. Replace the new power supply. V. Field of view with spoil: 1. Check whether the camera amplifier lens chip is dirty, with a small cotton ball stick to gently wipe it clean, or blow it clean with rubber. 2. There is dirt on the lens (spotting scope, objective lens, eyepiece), wipe it clean. 3. Slides with dirt, wipe it clean. VI. With high magnification objective image is not clear: 1. Blood film specimens (specimens) do not pass, or too much blood (coverslip cover is not in place). 2. Observe whether the brightness of the illumination lamp is appropriate. VII. Excessive eye fatigue when using: 1. No visual adjustment is easy to cause fatigue, to correctly adjust the visual degree. 2. Observe whether the lighting brightness is appropriate. VIII. The picture is not clear: 1. Check whether the coverslip has been added to the specimen. 2. Whether the fine tuning knob adjustment is in place;. 3. Detect whether there is dirt inside and outside the objective lens. 4. Check whether the coverslip used is standard and whether the oil of the coverslip is too thick. 5. Check whether the specimen is placed backwards. 6. Check whether the objective lens is covered with thick oil lens, if so, wipe it with wiping paper dipped in xylene. 7. Check whether the spotting scope aperture light bar is open too small, appropriate open large. 8. Check whether the position of the spotting scope is too low, if so, correct the position. IX. Image dark on one side: 1. Check the spotting scope in the center of the field of view or has been tilted. 2. Check whether the objective lens is in position, rotate it, so that it is positioned. 3. Check whether the specimen has been fixed, to reliable reinforcement.
  • ブランド: Unbranded
  • カテゴリー: 顕微鏡
  • Fruugo ID: 418260460-881781085
  • EAN: 4331342560447

配送と返品

24時間以内に発送

  • STANDARD: ¥2,549 - 間の配達 木 02 10月 2025–金 10 10月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Bear's Den
  • Guangzhou Yi'an Gongchuang Network Technology Co., Ltd.
  • Room 201, Area B, No. 280, Zhongshan Avenue East, Huangpu District
  • Guangzhou City, Guangdong Province
  • China
  • Guangzhou
  • CN
  • 511363
  • ojochweqd@outlook.com
  • 19065061059

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1,DERECHA,OFICINA 3,Fuenlabrada
  • Madrid
  • Spain
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • 34910602659