説明
Item Type: Coulombmeter
Model: VAC9610S
Material: ABS, PCB
Measurement range:
Voltage: 0.01-500v
Current: 0-1000A
Capacity: 0.001AH-65000AH
Energy: 0.00KWH-99999.9KWH
Time: 0-100 hours
Power value: 60KW
Temperature: 1-100 degrees Celsius
Accuracy:
Voltage: 1%
Current: 2%
Temperature: 2
Measurement rate: 20 times/second
Protection type and range
OVP (over voltage protection): 0.01-500v
LVP(under voltage protection): 0.01-500v
OCP(charge overcurrent protection): 0-1000A
NCP(Discharge overcurrent protection): 0-1000A
OTP(Over temperature protection): 0-100
Function introduction:
1, "BAT" battery capacity value setting, this parameter is to set the total measured battery capacity.
2, "BPC" battery remaining capacity percentage, you can set the remaining AH of the battery according to this value.
3, "OPP" set the over power protection value, if set the OPP value, when the actual output power value is greater than the set value, will prompt over power, and cut off the relay (self assigned).
4, "OVP" set the over voltage protection value, if set the OVP value, when the actual measured voltage value is greater than the set value, it will prompt over voltage, and cut off the relay (self contained).
5, "LVP" set the overvoltage protection value, if set the LVP value, when the actual measured voltage value is less than the set value, it will prompt the undervoltage, and cut off the relay (self assigned).
6, "NCP" set the overvoltage protection value, if the NCP value is set, when the actual measured charging current value is less than the set value, it will prompt overcurrent, and cut off the relay (self contained).
7, "OCP" set the overvoltage protection value, if the OCP value is set, when the actual measured discharge current value is less than the set value, it will prompt overcurrent, and cut off the relay (self assigned).
8, "OTP" set the over temperature protection value, if set the OTP value, when the actual measured temperature value is greater than the set value, will prompt over temperature, and cut off the relay (self assigned).
9, "ADS" communication address setting. Multi computer communication by setting the address to achieve multi computer communication.
10, "TTL" instrument power on the default relay output state, normally open or normally closed.
11, "CLR" no load current clear function, if the actual no load current is not 0, use this function to clear the no load current to 0.
-
ブランド:
Unbranded
-
カテゴリー:
電気計器
-
Fruugo ID:
396910143-847039116
-
EAN:
9081552115429