LS195 Gloss Meter Intelligent Stone Metal Glossometer Gloss Testing Equipment for Industry

¥23,190
+ 配送料¥899

LS195 Gloss Meter Intelligent Stone Metal Glossometer Gloss Testing Equipment for Industry

  • ブランド: Unbranded

LS195 Gloss Meter Intelligent Stone Metal Glossometer Gloss Testing Equipment for Industry

  • ブランド: Unbranded
希望小売価格: ¥36,290
価格: ¥23,190
得する金額: ¥13,100 (36%)
販売元:
¥23,190
+ 配送料¥899

在庫あり

以下の支払い方法を利用することができます

説明

LS195 Gloss Meter Intelligent Stone Metal Glossometer Gloss Testing Equipment for Industry

LS195 Gloss Meter Intelligent Stone Metal Glossometer Gloss Testing Equipment for Industry Item Type: Gloss Meter Model: LS195 Material: ABS Battery: 1 x Rechargeable lithium battery 3.7V 650mAh (Battery Included) Purpose: Sampling and comparison of gloss measurement Application: Paint, coating, ink, plastic, paper, ceramic tile, ceramic, stone, metal, electroplating layer Measuring Angle: 60° Measuring Spot: Approx. 9 x 15 mm / 0.4 x 0.6 in Minimum Size of Test Object: Approx. 20 x 10 mm / 0.8 x 0.4 in Measuring Range: 0-200GU Resolution: 0.1GU Repeatability: 0-100GU: ±0.2GU 100-200GU: ±0.2% of reading Reproducibility: 0-100GU: ±0.5GU 100-200GU: ±0.5% of reading Zero Error: 0.1GU Indication Error: 0-100GU: ±1.5GU 100-200GU: ±1.5% of reading System Language: Chinese, English Display: 240 x 128 dot matrix LCD Charging Interface: USB (Type C) Data Interface: USB Operating Temperature Range: 10-45 ℃, 0-85%RH (non condensing) Storage Temperature Range: -10-60℃, 0-85%RH (no condensation) QC Judgment: √ Ambient Temperature Compensation: √ How e: 1. Power on/off Power on: In the off state, short press the instrument button to power on. Shut down: Long press the instrument button to shut down; the instrument will automatically shut down when there is no operation for more than 3 minutes machine. 2. Parameter setting In the shutdown state, long press the instrument button for 3S to enter the parameter setting mode: A. Language (Language) Short press the button to select Chinese or English, long press the button for 3S to complete the setting, and enter the following setting item. B. Mode selection Short press the button to select normal mode or QC mode, long press the button for 3S to complete the setting, exit the setting and enter the calibration interface. 3. Equipment calibration Put the instrument on the standard board and turn on the opportunity to enter the calibration interface. The user can perform the calibration operation according to the calibration prompt, and the measurement interface will be entered after the calibration is passed. If the instrument is turned on without putting it on the standard board, it will skip the calibration and enter the measurement interface directly. If it prompts that the calibration failed, the possible reasons are as follows: The standard board is dirty, please wipe the standard board clean with a special lens cloth, and then buckle the host into the base. The host is not close to the standard board, please buckle it into the base again. When the ambient temperature changes significantly, the instrument temperature and the ambient temperature should be close to each other, and after confirming that the lens in the test port of the instrument and the standard plate of the base are not dew, restart the measurement. The attenuation of the light source can not be used normally, and it needs to be returned to the factory for inspection and repair. When the instrument prompts "Calibration failed", you can long press the button to skip the calibration. 4. Measure (1) Normal mode If the instrument is set to normal mode, after the calibration of the instrument is completed, remove the base and place the measuring port of the instrument on the surfaces of the object to be measured, and the instrument will display the measured value at that place in real time. Short press the button, the lower left corner of the interface displays the "HOLD" sign, and the measurement data is held on the LCD. If you need to measure again, press the button to cancel the "HOLD" state and return to the "Measuring" state. (2) QC mode If the instrument is set to QC mode, after the instrument is calibrated, remove the base, place the measuring port of the instrument on the surfaces of the object to be measured, and short-press the button to perform the measurement. After the measurement, the measured value will be judged whether it is qualified. The range of the upper and lower limits must be set by PC software. For specific operations, please refer to the "Gloss Meter Software Operation Manual".
  • ブランド: Unbranded
  • カテゴリー: 露出計
  • Fruugo ID: 397056493-847241192
  • EAN: 6921316718264

配送と返品

24時間以内に発送

  • STANDARD: ¥899 - 間の配達 木 11 12月 2025–金 19 12月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Room201,AreaB,No.280,Zhongshan Avenue East
  • Huangpu
  • Guangzhou
  • Guangdong
  • China
  • 518000
  • firzen.pan@gmail.com
  • +8619128656319

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659