説明
This module is mainly used for measuring DC voltage, current, active power, frequency and energy consumption, the module is without display function, the data is read through the RS485 interface.
<br>
<br>Features:
<br>
<br>It is mainly used for measuring DC voltage, current, active power, frequency and energy consumption.
<br>Comes with built in shunt, the current measure range is 0.01-10A.
<br>Physical layer use UART to RS485 communication interface, baud rate is 9600, 8 data bits, 2 stop bit, no parity.
<br>The application layer use the ModbusRTU protocol to communicate, it only supports function codes such as 0x03, 0x04,0x06, 0x41, 0x42, etc.
<br>Voltage threshold can be set, divide into high voltage and low voltage threshold, when the measured voltage exceeds the threshold, it can alarm.
<br>
<br>Specification:
<br>Brand: PEACEFAIR
<br>Model: PZEM-003
<br>Voltage:
<br>
<br>Measuring Range: 0.05-300V (When the test voltage is <7V, please use the independent power supply mode)
<br>Resolution: 0.01V
<br>Measurement Accuracy: 1%
<br>Current:
<br>
<br>Measuring Range: 0.01-10A
<br>Resolution: 0.01A
<br>Measurement Accuracy: 1%
<br>Power:
<br>
<br>Measuring Range: 0.1-3kW
<br>Resolution: 0.1W
<br>Measurement Accuracy: 1%
<br>Energy Consumption:
<br>
<br>Measuring Range: 0-9999kWh
<br>Resolution: 1Wh
<br>Measurement Accuracy: 1%
<br>Reset Energy: Use Software to Reset
<br>Over Voltage Alarm:
<br>
<br>Default High Voltage Threshold: 300V
<br>Default Low Voltage Threshold: 7V
<br>Communication Interface: RS485 Interface
<br>Working Temperature: -20~60℃
<br>Product Size: Approx. 9*6*2.3cm/3.5*2.4*0.9inch
<br>Weight: Approx. 72g~92g / 2.5oz~3.2oz
<br>Description Resolution
<br>Voltage value 1LSB correspond to 0.01V
<br>Current value 1LSB correspond to 0.01A
<br>Power value low 16 bits 1LSB correspond to 0.1W
<br>Power value high 16 bits
<br>Energy value low 16 bits 1LSB correspond to 1Wh
<br>Energy value high 16 bits
<br>High voltage alarm status 0xFFFF is alarm,0x0000 is not alarm
<br>Low voltage alarm status 0xFFFF is alarm,0x0000 is not alarm
<br>
<br>
<br>
<br>Register address Description Resolution
<br>0x0000 High voltage alarm threshold(5~350V),
<br>default is 300V 1LSB correspond to 0.01V
<br>0x0001 Low voltage alarm threshold(1~350V),
<br>default is 7V 1LSB correspond to 0.01V
<br>0x0002 ModbusRTU address The range is
<br>0x0001~0x00F7
<br>
<br>
<br>
<br>Optional Kit
<br>#1 1 x DC Consumption Meter
<br>#2 1 x DC Consumption Meter
<br>1 x RS485 to USB Cable
<br>
<br>Note:
<br>
<br>RS485 interface is passive output, need external connect 5V power supply and the external power supply should >100mA.
<br>When the input test voltage is less than 7V, it must supply 5V independent work voltage through USB port.
<br>Do NOT use the USB port bring by your PC to be the independent power supply, otherwise it may damage your PC.<br>1、It is mainly used for measuring DC voltage, current, active power, frequency and energy consumption
<br>2、Comes with built in shunt, the current measure range is 0.01-10A
<br>3、Physical layer use UART to RS485 communication interface, baud rate is 9600, 8 data bits, 2 stop bit, no parity
<br>4、The application layer use the ModbusRTU protocol to communicate, it only supports function codes such as 0x03, 0x04,0x06, 0x41, 0x42, etc
<br>5、Voltage threshold can be set, divide into high voltage and low voltage threshold, when the measured voltage exceeds the threshold, it can alarm
-
ブランド:
Unbranded
-
カテゴリー:
特殊電源スイッチ
-
重さ:
0.1
-
長さ:
5
-
Width:
5
-
高さ:
5
-
Fruugo ID:
347872642-759951790
-
EAN:
929768646667