PH/ORP Water Quality Detector 0.01pH/1mV Resolution with Energy Saving LCD Backlight for Wastewater Treatment AC220V NO.0881

¥29,790
配送料無料

PH/ORP Water Quality Detector 0.01pH/1mV Resolution with Energy Saving LCD Backlight for Wastewater Treatment AC220V NO.0881

  • ブランド: Unbranded

PH/ORP Water Quality Detector 0.01pH/1mV Resolution with Energy Saving LCD Backlight for Wastewater Treatment AC220V NO.0881

  • ブランド: Unbranded
希望小売価格: ¥35,790
価格: ¥29,790
得する金額: ¥6,000 (16%)
販売元:
¥29,790
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

Feature 1Continuous Measurement: PH110 industrial pH meter is an intelligent upgrade product of industrial acidity meter, which can continuously measure and control the pH value of sewage. 2Function: PH tester can perform PH/ORP measurement, upper and lower limit control, current output, and digital communication. 3LCD Backlight: LCD backlight can choose energysaving mode, and it will be automatically turned off at regular intervals. Audible alarm can be switch on and off. 4Meter Mode: ORP water quality tester has meter mode isolation and transmission port, and the maximum loop resistance is greater than 300. 5Scope of Application: PH tester is suitable for city sewage treatment plants, chemicals, printing and dyeing, papermaking, pharmaceuticals, electroplating and environmental protection and other fields.Item Type: ORP Water Quality TesterMaterial: ABSMeasuring Range: PH(0 14 pH) ;ORP( -1900 - +1900 mV)Accuracy: + 0.02 pH; + 1 mVResolution: 0.01pH; 1mVStability: 0.02 pH/24 Hours; 3 mV/24 HoursPH Standard Solution: 4.00/6.86/9.18Display Mode: 128x64 dot Array LCDTemperature Compensation: 0100 C Manual/Auto (NTC10K)Signal Output: 4-20mA Isolation Protection Output, Maximum Loop Resistance 300Alarm Output: One Set of High and Low Limit Alarm Contacts (3A/250 V AC), Normally Open Contact RelayPower Supply: AC220VPower Consumption: 3WEnvironmental Conditions: (1) Temperature 060 (2) Humidity85%RHBoundary Dimension: Approx. 96 x 96 x 110mm / 3.8 x 3.8 x 4.3in (H x W x D)Hole Size: Approx. 92 x 92mm / 3.6 x 3.6in (H x W)Electrode Length: Approx. 5meters / 5.5 ORP Electrode .wang-edit-text{ font-family:'Arial' !important; } .wang-edit-text table { border-top: 1px solid #000; border-left: 1px solid #000; } .wang-edit-text table td, .wang-edit-text table th { border-bottom: 1px solid #000; border-right: 1px solid #000; padding: 3px 5px; } .wang-edit-text table th { text-align: center; }Package List1 x ORP Water Quality Tester1 x Electrode1 x User ManualNote1. The electrode should be cleaned regularly. When disassembling and cleaning the electrode, you cannot break the oxygen permeable membrane, and you cannot use filter paper to rub the oxygen permeable membrane on the electrode to avoid damaging the oxygen permeable membrane.2. The cable connector must be kept clean, and must not be exposed to moisture or water.3. When the displayed value of the instrument differs greatly from the actual value or cannot measure the low content of oxygen, the electrolyte inside the oxygen electrode may dry up and needs to be refilled with electrolyte, generally the maintenance work of replacing or adding electrolyte is carried out once every 6 months; the spare membrane head needs to be replaced when the permeation membrane ruptures. Each time after replacing or adding electrolyte or replacing the spare membrane head, the electrode needs to be repolarized and calibrated. The specific steps are as follows: put the electrode upside down, unscrew the black part of electrode shielding at the lower part of the electrode, remove the membrane head, pour off the old liquid in the cavity, fill in the original electrolyte, do not fill it too full, and let the excess electrolyte drain off. Just screw it tightly and make sure the membrane can stick to the head of the electrode core. After replacing the electrolyte well, the polarization and calibration should be done again.4. Electrode polarization: After the electrode is connected to the instrument, it will be polarized when it is continuously energized for more than 0.5 hours, and the electrode can be calibrated only after it is polarized.
  • ブランド: Unbranded
  • カテゴリー: 水分計
  • Fruugo ID: 296177415-662385428
  • EAN: 7987249320881

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Not suitable for children under 36 months. Choking Hazard. Adult supervision recommended

配送と返品

3日間以内に発送

  • STANDARD: 無料 - 間の配達 木 04 12月 2025–火 23 12月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Advance Parts Zone
  • Shenzhen Mike Technology Co. Ltd.
  • No. 108 Donghuan 1st Road
  • Yousong Technology Building 4-B01
  • Shenzhen
  • CN
  • 518000
  • miekortech@hotmail.com
  • +8613714168241

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • Ben XU
  • REP Europe GmbH
  • Annastr. 9 B
  • Griesheim
  • Germany
  • 64347
  • info@rep-europe.de
  • +4915751253212
  • http://www.rep-europe.de/