RCMF‑1 Pulse Generator Servo Motor Speed Regulation Fixed Length Timing Controller Potentiometer

¥6,390
配送料無料

RCMF‑1 Pulse Generator Servo Motor Speed Regulation Fixed Length Timing Controller Potentiometer

  • ブランド: Unbranded

RCMF‑1 Pulse Generator Servo Motor Speed Regulation Fixed Length Timing Controller Potentiometer

  • ブランド: Unbranded
希望小売価格: ¥8,190
価格: ¥6,390
得する金額: ¥1,800 (21%)
販売元:
¥6,390
配送料無料

在庫あり

以下の支払い方法を利用することができます

説明

Feature: 1. The measurement data level function symbol display, large screen high definition. 2. Multi‑turn potentiometer speed adjustment, precise adjustment of the motor, allowing the motor to run at high speed. 3. The generator uses precision equipment, the molding process is good, and the tiny details are carefully perfected. 4. RCmf‑1 pulse generator can control stepper motor, servo motor, motor speed 00‑1000 rpm, square wave, stepless adjustable. 5. ACC acceleration setting (1‑99) 1 is the fastest, 99 is the fastest, load reset is slower, the default value is 5. Specification: Condition: 100% Brand NewItem Type: Pulse GeneratorMaterial: ABSColor: As Pictures ShownRCmf-1 pulse generator can control stepper motor, servo motor, motor speed 00-1000 rpm, square wave, stepless adjustable. External start-stop and direction can realize external control. It has the functions of speed regulation and fixed length. 1. Display description: The digital tube displays the current speed value in the running state or the stop state, and the unit is rpm. Display the set parameter code or parameter value in the setting state 2. Parameter setting: In the stop loading state, long press the stop button, ACC appears, and then press the stop button to display the ACC parameter value, press the arrow keys and offline button to modify, press the stop button to confirm after the modification, and return to the ACC state , Press the arrow keys to display tAb, press again to display Modo, then press to display Model, press again to return to the ACC parameter setting same as ACC, press the offline key to exit the parameter setting to the stop state, ACC acceleration setting (1-99) 1 is the fastest, 99 is the fastest, load reset is slower, the default value is 5 tAb subdivision setting (1-64) This value is set according to the drive, and should be consistent with the drive setting. When the setting is consistent, the displayed speed is the actual speed, and the default value is 10. When run (0-1) is set to 0, it will stop when powered on, and it will run when powered on. The default value is 0 IN-S running stop input setting default value 0 0 Terminal 3 is connected to start, disconnected to stop, the direction is terminal 4 connects forward, disconnects reverse 1 Terminal 3 Press once to start, press again to stop, the direction is terminal 4 Press to stop 2 Terminal 3 click to start, terminal 4 click to stop 3Terminal 3 Press the forward rotation to start, press again to stop, press the wire end 4 Press to reverse to start, press again to stop 4 Terminal 3 is connected to start forward, disconnected to stop, terminal 4 connected to reverse to start, disconnected to stop Mode operating mode setting (0-3) 0 speed control, 1 fixed-length control, 2 continuous control, 3 reciprocating control, the default value is 0 in fixed-length mode, press the stop button to set P-01 in the stop state, long press the stop button to be Have d1A, d1b In continuous mode and round-trip mode, press the stop button to set P-01, P-02, P-03 in stop state In speed control mode and round trip mode, x1, x2 limit is valid, and the direction will be reversed when encountered. P-01 length value, number of pulses=P-01 x d1A/d1b doub: the default magnification setting is 10-1000 rpm adjustable P-02 delay value, the unit is set to 20-2000 rpm adjustable in milliseconds P-03 times value, continuous running times value is set to 30-3000 rpm adjustable. 3 Operation description: Panel start or external terminal start, adjust potentiometer to adjust speed during operation. 3. Operation Description: The panel stops or the external terminal stops, and it displays 0 when it stops. If you need to display the current adjusted speed of the potentiometer in the stopped state, you can press the offline button, and the potentiometer is also adjusted to modify the speed when the offline light is on. To change the direction of the value, press the panel arrow keys or external arrow keys. Package List: 1 x Pulse Generator1 x Manual
  • Fruugo ID: 391564586-838194095
  • EAN: 7354012105158

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark
安全上の警告: Warning: Please read the product instructions carefully before use to ensure correct use.
シリアルナンバー: 7354012105158

配送と返品

2日間以内に発送

  • STANDARD: 無料 - 間の配達 火 28 10月 2025–火 04 11月 2025 - 無料

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • No. 1-1, Door 57
  • Shihua Village
  • Qingshan District
  • Wuhan
  • CN
  • 430000
  • goldxinks@163.com
  • 0086 17786498762
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795