説明
Features:
100% brand new and high quality
A
pH meter is an electronic device used for measuring the pH which is
either the concentration of Hydrogen ions in an aqueous solution or the
activity of the Hydrogen ions in an aqueous solution.
The pH will
indicate if the solution is acidic or basic, but is not a measure of
acidity or alkalinity.
pH meters work in liquids though special probes
are sometimes used to measure the pH of semi-solid substances.
A pH
meter consists of a special measuring probe (a glass electrode)
connected to the body which measures and displays the pH reading.
Specification:
Instrument Level:
Grade 0.01
PH Measuring range:
PH 0.00~14.00pH
PH basic measurement error:
± 0.05pH
Instrument Repeatability:
±0.03pH
Solution temperature compensation range:
0 ~ 60°C
instrument repeatability
0.03pH
mV measuring range:
-1400mV~+1400mV
temperature range:
-10 ~ 60 ; 0.1°C
Battery:
9V Battery (not included)
Display:
Large LCD segment type display with back light
Working temperature:
0 ~ 35°C
Working humidity:
0-80% R H ( Non Gel)
Weight
Approx.650g/22.9oz
Product Size
17.2*6.2*3cm/6.8*2.4*1.2in
Explanation of appearance:
1. ON/OFF
2. mode button
3. MAX/MIN HOLD button
4. C/F selection button
5. CAL/back light button
6. LCD Display
7. electrode plug
8. Electrode assembly
9. Electrode liquid storage bottle
LCD Display:
1. Battery indication
2. HOLD function
3. MIN Measurement
4. MAX Measurement
5. PH measured value
6. READ fuction
7. Temperature Measured vale
Normal Condition of use:
(1)
the environment temperature (0 ~ 35) ;
(2)
the relative humidity is not more than 80%;
(3)
measured solution temperature: (5 ~ 60 );
(4)
power supply: 9V DC battery X 1pc (006P);
(5)
no significant vibration;
(6)
in addition to the earth's magnetic field without external magnetic field outside interference.
User's Guide:
Open
the battery door that located at the back of the instrument, insert a
new 9V battery into this compartment with correct polarity. If you have
replaced with a new PH composite electrode, please do the calibration
before use this unit to measure.
If measuring interval time is short, one month calibration once is enough.
This instruction use three point calibration method for a librate this unit, please following the step one by one
The unit and calibration solution must be calibrated at ambient environment temperature 25 C +/-2 C.
(1)
Press "MODE" key go to three different calibration mode (CAL 1), (CAL 2) and (CAL 3).
(2)
according
to the "mode" button instrument into the correction state, respectively
into "C4.0" "C6.86" "C9.18" three states cycle scintillation
indicating symbol.
(3)
Correction steps are as follows:
A: PH4.00
buffer solution calibration: Press"MODE" key go to (CAL 1) icon shown
and flashing, rinse the PH electrode with distilled water, immerse the
electrode in the PH4.00 buffer solution, wait for the electrode become
stable, you should find the value of mV don't change and state at same
value, this time press (CAL ) key more than 3 seconds. until (4.00)
flashing stop and disappeared, so the PH4.00 calibration completed.
B: PH6.86
buffer solution calibration: Press "MODE" key two times go to (CAL 2)
icon shown and flashing, rinse the PH electrode with distilled water,
immerse the electrode in the PH6.86 buffer solution, wait for the
electrode become stable, you should find the value of mV don't change
and state at same value, this time press(CAL )key more than 3
seconds.until (6.86) flashing stop and disappeared, so the PH6.86
calibration completed
C: PH9.18 buffer solution
calibration: Press "MODE" key three times go to (CAL 3) icon shown and
flashing, rinse the PH electrode with distilled water, immerse the
electrode in the PH9.18 buffer solution, wait for the electrode become
stable, you should find the value of mV don't change and state at same
value, this time press(CAL) key more than 3 seconds.until (9.18)
flashing stop and disappeared, so the PH9.18 calibration completed.
(4)
normal measurement mode: The fa
-
Fruugo ID:
437731980-917464238
-
EAN: