W3230 Relay Output Digital Temperature Controller -55~120c Thermostat Regulator Heating Cooling Control Switch 10a 220v/20a 12v

¥2,149
+ 配送料¥1,099

W3230 Relay Output Digital Temperature Controller -55~120c Thermostat Regulator Heating Cooling Control Switch 10a 220v/20a 12v

  • ブランド: Unbranded

W3230 Relay Output Digital Temperature Controller -55~120c Thermostat Regulator Heating Cooling Control Switch 10a 220v/20a 12v

  • ブランド: Unbranded
希望小売価格: ¥6,590
価格: ¥2,149
得する金額: ¥4,441 (67%)
販売元:
¥2,149
+ 配送料¥1,099

在庫あり

以下の支払い方法を利用することができます

説明

Dear customer: Thank you for choosing my store for shopping. The following are the matters needing attention for shopping: A. Economic transportation: detailed tracking information will not be included. Most of the packages will cause delayed delivery within the expected delivery time, so you need to be patient B. Each product link: There will be different option variants. If you do nt know how to select the product you want, please contact me, I will be honored to solve this problem for you. C. When you receive the package, there is product damage / product problem / error product and shipping problem, please contact me in time, I will solve it for you D. If you are a wholesaler / distributor, a large number of orders and quantities, to provide you with factory prices, and hope to be honored to reach a partner with you GOOGZON store: I wish you a happy life Power Supply:DC 12V/ AC 110V-220V Temperature Control Range:-55-120 Resolution Ratio: 0.1C(-9.9-99.9); 1C(other range) Color of Displaying: red/blue Measurement accuracy: 0.1C Control accuracy: 0.1C Sensor: NTC10K Waterproof sensor Output: Relay Contact Capacity 20A 12V / 10A 220V Environmental requirements: -10-60C , humidity 20%-85%RH Dimension:79mm *43mm*26mm Cutting Size:73mm*39mm Sensor wire: 1 meter Method of Use At this time, the display is displayed as measuring temperature. Press the SET key once and the display temperature flashes. Press +- to SET the required temperature (+- can quickly rise and fall) After the setting is complete, press Set to confirm and return. The output of the thermostat is 20A relay, which can meet various high-power loads. If the control circuit is well connected, it can supply power to the thermostat. At this time, the display screen displays the ambient temperature. Indicator and nixie tube status description Indicator: Blinking indicates delay in starting cooling or heating. Steady on indicates that the relay is closed Digital tube: display LL for the sensor open circuit, please connect the sensor according to the instructions; If HH is out of the measuring range, the thermostat will disconnect the relay forcibly. Display -- high temperature alarm Parameter Function Description Long press SET for 5 seconds to enter the main menu setting, press +- to switch to P0... P6, long press SET or 10 seconds no key action controller automatically confirm return. P0 cooling and heating mode Long press SET for 5 seconds to display P0, press SET once to SET the working mode, press +- to switch [H for heating mode] [C for cooling mode], press SET once to return, long press Set or 10 seconds without key action the controller will automatically confirm completion. Refrigeration mode: when the temperature measurement value is greater than or equal to the temperature setting point, the refrigeration relay draws, and the refrigerator starts; When the temperature measurement value is less than the temperature setting point-return difference, the refrigeration relay is disconnected and the refrigerator is closed. Heating mode: When the temperature measurement value is less than the temperature setting point, the heating relay draws and the heater starts; When the temperature measurement value is greater than or equal to the temperature setting point + return difference, the heating relay is disconnected and the heater is closed. P1 back error setting Press +- to switch to P1. Press SET once to SET the return difference value. Press +- to SET the return difference value to 0.1-15. Refrigeration mode: when the temperature measurement value is greater than or equal to the set value, the relay suction, the refrigerator starts; When the temperature measurement value is less than the set value - return value, the relay is disconnected and the cooler is closed. For example, when the environment is 30, the set value is 25, and the return difference is 2. After power on, the closed refrigerator of the relay starts. When the refrigeration reaches 23, the refrigerator of the relay will be disconnected and shut down. Heating mode: when the temperature measurement value set value, relay suction, heater start; When the temperature measurement value is not less than the set value + return value, the relay is disconnected and the heater is closed. For example, when the environment is 10, the set value is 25, and the return difference is 2. After power-up, the closed heater of the relay will start. When the heater is heated to 27, the relay will disconnect and the heater will close. P2 Set the upper limit for the maximum temperature In order to avoid the danger of oversetting the temperature due to misoperation by others, the thermostat has the maximum setting upper limit function, which limits the setting range of the maximum temperature setting point controlled by the thermostat. Press +- to switch to P2. Press SET once to SET the maxi
  • Fruugo ID: 206054694-438486799
  • EAN: 9423242351531

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

安全上の警告: WARNING: TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN.

配送と返品

24時間以内に発送

  • STANDARD: ¥1,099 - 間の配達 木 02 10月 2025–金 10 10月 2025

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • CREA
  • CREA
  • 1-3 Boulevard Charles de Gaulle Colombes 92700 FR
  • Colombes
  • FR
  • 92700
  • xmchymx@outlook.com
  • 86-13312976782
  • https://www.fruugo.co.uk/shenzhen-huiwang-technology/m-14383

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • E-CrossStu GmbH
  • E-CrossStu GmbH
  • Mainzer Landstr.69,60329 Frankfurt am Main,Hessen, Deutschland
  • Frankfurt am Main
  • DE
  • 60329
  • E-CrossStu@web.de
  • +4969330000000
  • https://www.fruugo.co.uk/shenzhen-huiwang-technology/m-14383