XY-CD60 Battery Battery Charging Control Module Under-voltage Deficit Protector Full of DC Voltage Protection

¥2,099
+ 配送料¥2,149

XY-CD60 Battery Battery Charging Control Module Under-voltage Deficit Protector Full of DC Voltage Protection

  • ブランド: Unbranded

XY-CD60 Battery Battery Charging Control Module Under-voltage Deficit Protector Full of DC Voltage Protection

  • ブランド: Unbranded
希望小売価格: ¥5,190
価格: ¥2,099
得する金額: ¥3,091 (59%)
販売元:
¥2,099
+ 配送料¥2,149

在庫あり

14日間返品ポリシー

支払い方法:

説明

XY-CD60 Battery Battery Charging Control Module Under-voltage Deficit Protector Full of DC Voltage Protection

100% brand new and high quality Features: Made of high quality material, sturdy, durable and practical to use. Great for fixing overload and low voltage, protects the battery from undervoltage, protects the battery from overcharging, and protects the load control, prolong battery life. When the battery voltage is insufficient, disconnect the load and connect the charger. When the battery voltage is too high, disconnect the charger and connect the load. Adjustable parameters and LCD screen, show you the parameters clearly, easy to use. With a control voltage 6-60V, it is suitable for batteries, lithium batteries, etc.. Battery Charger Controller Module only,other accessories demo in the picture is not included. Charging mode IN: By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage is less than or equal to the lower limit voltage dn, the relay turns on and the charger starts charging the battery; when the battery voltage is more than or equal to the upper limit voltage UP, the relay disconnects to complete an automatic charging; when the relay turns on, IN flickers, indicating that it is charging. Discharging mode OUT: By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage is greater than or equal to the upper limit voltage UP, the relay turns on and starts discharging; when the battery voltage is less than or equal to the lower limit voltage dn, the relay turns off and completes an automatic discharging function; when the relay turns on, the OUT flickers, indicating that it is discharging. Tips: This product is a simple voltage controller. It can turn on and off the output by relay. It only plays the role of switching, and can not change the voltage. Functional instruction: 1. Calculation of Voltage Percentage: Battery Voltage/(Upper Voltage-Lower Voltage) 2. Key function: UP: Short press display % and time, long press 5 seconds to switch mode; charging mode: IN, discharge mode: OUT. SET: Short press to check the parameters currently set; long press to enter the parameter setting interface, set UP: voltage upper limit, dn: voltage lower limit, OP: turn-on time, dOP: delay turn-on time (0-999 seconds), FOP: forced turn-on time (0-10 seconds) in discharge mode. DOWN: Turn off/on electric relay enable (emergency stop function) turn off, LCD display OFF, relay disconnect: long press to set the status of LCD backlight, L-P: OFF backlight constant brightness, ON: Backlight automatically extinguishes after 5-10 minutes; after extinguishing, press any keys to wake up. 3. Parameter Settings a. Enter the parameter setting interface by pressing the SET; b. After entering the parameter setting interface, switch the setting parameters by short pressing SET; c. After choosing parameters, it can be set by UP/DOWN key, supporting short press or long press. d. If you want to set other parameters, repeat steps b and c; e. After all parameters are set, long press SET to exit and save; 3.1 Charging/Discharging Time Control Function 1) When the time parameter OP is non-zero, start charging/discharging time control. 2) When the relay turns on a charge/discharge, the countdown begins; when it is completed, the relay is automatically disconnected to complete a charge/discharge process; if the time is completed, under the charging mode, the detection voltage is less than the lower limit voltage dn or in the discharge mode, the detection voltage is larger than the upper limit voltage UP, and the charging time control function is automatically turned off and flashes. Indicate H: ER reminds users that time parameter setting is unreasonable; press any key to stop flickering; 3) When the charging/discharging time control is not turned on, the product will record a complete time. When entering the time display interface, flashing shows the charging time, then exiting the time display interface or clearing the next time the charging is turned on (relay is turned on). 3.2 Automatic parameter detection: When the parameters are set and exit, if the lower voltage limit DN is larger than the upper voltage up, the system will flicker to display "ERR" as a reminder. 3.3 Delayed turn-on function (0-999 seconds): Completion of a charge/discharge, the interval between re-opening; 3.4 Discharge Conduction Forced Start Time (0-10S): After satisfying the relay conduction condition, the relay is forced to turn on (0-10S) to detect the battery voltage again. This function is mainly aimed at discharging function. Some test loads will pull down the lower limit voltage instantaneously at the moment of conduction, which will lead to the disconnection of the relay and the failure of normal discharge process. Analysis of Common Faults: Question 1: How many V levels are
  • Fruugo ID: 77077256-155742627
  • EAN: 8458017362888

製品安全情報

以下に概説するこの製品に固有の製品安全性情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製品安全ラベル

CE Mark

配送と返品

24時間以内に発送

  • STANDARD: ¥2,149 - 間の配達 金 02 1月 2026–水 07 1月 2026

中国より発送。

ご注文の商品は、お客様の仕様に従い、万全の状態で配送されるように最善を尽くしています。しかし、もし注文に抜けがあったり、注文したものと違う商品が届いたり、注文に満足できないその他の理由がある場合は、注文全体やその中のいずれかの商品を返品し、その全額の返金を受けることができます。 全額返金ポリシーを見る

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

製造業者:
次の情報は、Fruugoで販売される関連製品の製造業者の連絡先詳細です。

  • Shenzhenshitaimusenfangzhipinyouxiangongsi
  • Shenzhenshitaimusenfangzhipinyouxiangongsi
  • GuangmingquyutangjiedaoyuquanluxinyigongyeyuandiCdongsushe307
  • Shenzhenshi
  • China
  • 518107
  • fvytt576@hotmail.com
  • 18823315680

EUにおける責任者:
次の情報は、EUにおける責任者の連絡先情報の概要です。ここで言う責任者とはEUに拠点を置く指定経済事業者で、EU域内で販売される関連製品に関するコンプライアンス義務を負う者のことです。

  • CrossStYAting
  • E-CrossStu GmbH
  • 69 Mainzer Landstrasse
  • Frankfurt am Main
  • Germany
  • 60329
  • E-crossstu@web.de
  • +4969332967674